4. TROUBLE SHOOTING
- 53 -
(3) Checking PLL Control Signal
Test Points
Waveform
Checking Flow
S_DATA
S_CLK
S_EN
RF_PWR_DWN
Figure 4-4.
Check TP 401.
Lev el i s High?
Yes
Control Signal is OK
See next Page to check
ANT SW & Mobile SW
No
Check S_DATA,
S_CLK, S_EN.
Check if there is
Any Major Difference
Refer to Graph 3-1
3-2
Simil ar?
Yes
No
Download the SW
Download the SW
Graph 4-2(a)
Graph 4-2(b)