60
2008 Product Data
7. Refrigerant cycle diagram
Model no: AS-W2468*H1, AS-W2465DH2
Indoor Unit
Outdoor Unit
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
EEV
Compressor
Gas Side
3-Way Valve
3-Way Valve
Liquid Side
Cooling
Heating
Reversing Valve
Th1
Th2
Th3
Th5
Th4
Th6
Th7
LOC.
Description
PCB Connector
Th1
Thermistor for indoor air temperature
CN_TH1(INDOOR)
Th2
Thermister for indoor pipe(in) temperature
Th3
Thermister for indoor pipe(out) temperature
CN_TH2(INDOOR)
Th4
Thermistor for outdoor air temperature
CN_TH2(OUTDOOR)
Th5
Thermister for outdoor pipe temperature
Th6
Thermistor for discharge pipe temperature
CN_TH3(OUTDOOR)
Th7
Thermistor for suction pipe temperature
Summary of Contents for AS-W0964GG1
Page 1: ...5RMA2 01A Inverter Single 50Hz R410A ...
Page 32: ...2008 Product Data 31 5 Dimensional drawings Indoor units 5 1 Indoor Units ...
Page 33: ...32 2008 Product Data 5 Dimensional drawings Indoor units ...
Page 34: ...2008 Product Data 33 5 Dimensional drawings Indoor units ...
Page 36: ...2008 Product Data 35 5 Dimensional drawings Indoor units ...
Page 40: ...2008 Product Data 39 5 Dimensional drawings Outdoor units 1 5 2 Outdoor Units ...
Page 41: ...40 2008 Product Data 5 Dimensional drawings Outdoor units 1 ...
Page 46: ...2008 Product Data 45 6 Wiring diagrams Indoor Unit Models AS W096ADR0 AS W126ADR0 ...
Page 48: ...2008 Product Data 47 6 Wiring diagrams Indoor Unit Models AS W1868 H1 Models AS W2463 H3 ...
Page 49: ...48 2008 Product Data 6 Wiring diagrams Indoor Unit Models AS W2468 H1 ...
Page 52: ...2008 Product Data 51 Models AS W096ADR0 AS W126ADR0 6 Wiring diagrams Outdoor units ...