Connect the cable to the Indoor unit.
Connecting the cable between indoor unit and outdoor unit
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board
individually according to the outdoor unit connection.
(Ensure that the color of the wires of the outdoor unit and the terminal No. are the same as those of the
indoor unit.)
Air
Conditioner
Main power source
Circuit Breaker
Use a circuit breaker
or time delay fuse.
• If a power plug is not to be used, provide a circuit
breaker between power source and the unit as
shown below.
Connecting the cable between indoor unit and outdoor unit
CAUTION
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2
The power cord connected to the outdoor unit
should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by
HAR or SAA).
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H07RN-F
approved by HAR or SAA).
20mm
7.5mm
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2
20mm
7.5mm
8.5mm
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 2.5mm
2
8.5mm
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 3.5mm
2
30k, 32k
36k, 38k
4(N)
Terminals on the indoor unit
3(L)
5
6
7
6
7
4(N)
Terminals on the outdoor unit
Color of Wires
POWER INPUT
Color of Wires
• Cooling & Heating Models
3(L)
2(N)
1(L)
5
G/Y
BROWN BLUE
RED
WHITE BLACK
RED
WHITE BLACK
G/Y
BROWN BLUE
2(N)
Terminals on the indoor unit
1(L)
3
4
6
4(N)
Terminals on the outdoor unit
Color of Wires
POWER INPUT
Color of Wires
• Cooling Only Models
3(L)
2(N)
1(L)
5
G/Y
BROWN BLUE
WHITE RED
WHITE RED
G/Y
BROWN BLUE