background image

Owner's Manual  

5

ENGLISH

Safety Precautions

Be very careful about product transportation. 

• Only one person should not carry the product if it weighs more than 20 kg.
• Some products use PP bands for packaging. Do not use any PP bands for a means of transportation. It is dangerous.
• Do not touch the heat exchanger fins. Doing so may cut your fingers.
• When transporting the outdoor unit, suspending it at the specified positions on the unit base. Also support the outdoor unit

at four points so that it cannot slip sideways.

Safely dispose of the packing materials.

• Packing materials, such as nails and other metal or wooden

parts, may cause stabs or other injuries.

• Tear apart and throw away plastic packaging bags so that chil-

dren may not play with them. If children play with a plastic bag
which was not torn apart, they face the risk of suffocation.

Turn on the power at least 6 hours before starting
operation.(In case of outdoor 
temperature below 10°C)

• Starting operation immediately after turning on the main

power switch can result in severe 
damage to internal parts. Keep the power switch turned on
during the operational season.

Do not touch any of the refrigerant piping during and
after operation.

• It can cause a burn or frostbite.

Do not operate the air conditioner with the panels or
guards removed.

• Rotating, hot, or high-voltage parts can cause injuries.

Do not directly turn off the main power switch after
stopping operation.

• Wait at least 5 minutes before turning off the main power

switch. Otherwise it may result in water leakage or other
problems.

Auto-addressing should be done in condition of connect-
ing the power of all indoor and outdoor units. Auto-
addressing should also be done in case of changing the
Indoor unit PCB.

Use a firm stool or ladder when cleaning or maintain-
ing the air conditioner. 

• Be careful and avoid personal injury.

Do not insert hands or other objects through the air
inlet or outlet while the air conditioner is plugged in. 

• There are sharp and moving parts that could cause per-

sonal injury.

Avoid a place where rain may enter since the HR unit
is for indoor

• There is risk of property damage, failure of product or elec-

tric shock.

Install the HR unit at a place in which it is not affected
by operation mode changing noise.

• Installation within cell such as meeting room etc, may dis-

turb business due to noise.

Summary of Contents for ARWB100DA2

Page 1: ...ER Please read this manual carefully before operating your set and retain it for future reference ARWN100LA2 ARWN100DA2 ARWN200DA2 ARWN80BA2 ARWN160BA2 ARWN200LA2 ARWB100DA2 ARWB200DA2 ARWB80BA2 ARWB160BA2 TYPE Outside unit MODELS ENGLISH ESPAÑOL PORTUGUESE ...

Page 2: ...t Ask the dealer or an authorized technician to install the air conditioner Improper installation by the user may result in water leak age electric shock or fire Always ground the product There is risk of fire or electric shock Always intstall a dedicated circuit and breaker Improper wiring or installation may cause fire or electric shock For re installation of the installed product always con tac...

Page 3: ...mixed with the original refrigerant the refrigerant cycle may malfunction and the unit may be damaged Do not reconstruct to change the settings of the pro tection devices If the pressure switch thermal switch or other protection device is shorted and operated forcibly or parts other than those specified by LGE are used fire or explosion may result Do not open the inlet grill of the product during ...

Page 4: ...rotection against noise The inverter equipment private power generator high frequen cy medical equipment or radio communication equipment may cause the air conditioner to operate erroneously or fail to oper ate On the other hand the air conditioner may affect such equipment by creating noise that disturbs medical treatment or image broadcasting Do not install the product where it is exposed to sea...

Page 5: ...the power switch turned on during the operational season Do not touch any of the refrigerant piping during and after operation It can cause a burn or frostbite Do not operate the air conditioner with the panels or guards removed Rotating hot or high voltage parts can cause injuries Do not directly turn off the main power switch after stopping operation Wait at least 5 minutes before turning off th...

Page 6: ...6 Outdoor Unit ...

Page 7: ...CIONADO Antes de operar su producto lea atentamente este manual de instrucciones y guárdelo para futuras referencias ARWN100LA2 ARWN100DA2 ARWN200DA2 ARWN80BA2 ARWN160BA2 ARWN200LA2 ARWB100DA2 ARWB200DA2 ARWB80BA2 ARWB160BA2 TIPO Unidad de exterior MODELO ESPAÑOL ...

Page 8: ...jase a su distribuidor o a un técnico autorizado para la instalación del sistema de aire acondicionado Una instalación inadecuada por parte del usuario puede generar fugas de agua descargas eléctricas o un incen dio Ponga siempre el producto a tierra Existe riesgo de fuego o descarga eléctrica Instale siempre un circuito e interruptor dedicados para el producto Una instalación o cableado incorrect...

Page 9: ...geno en la habitación No utilice el medidor del colector con el refrigerante R22 Utilice el medidor del colector para presiones elevadas R410A además de para el llenado estable de refriger ante No mezcle ni utilice el conducto R22 o los dispositivos de instalación utilizados hasta el momento La mezcla del aceite de R22 y de R410A puede deteriorar el funcionamiento de la unidad debido a la hidrólis...

Page 10: ...ad en un hospital en una estación de comunicación o en un lugar similar ofrez ca suficiente protección frente a las interferencias El equipo de inversión el generador de potencia privado el equipamiento médico de alta frecuencia o los equipos de comunicación por radio pueden hacer que el sistema de aire acondicionado no funcione con normalidad llegan do incluso a no funcionar Por otro lado el sist...

Page 11: ...odrían sufrir daños importantes Mantenga el interruptor de alimentación conectado durante el período operativo No toque ningún conducto de refrigeración durante o después del funcionamiento Podría sufrir daños por quemaduras o congelación No accione el sistema de aire acondicionado si ha reti rado los dispositivos de protección Las piezas giratorias calientes o de alto voltaje pueden ocasionar dañ...

Page 12: ...6 Unidad Externa ...

Page 13: ...ONADO Leia por favor este manual atentamente antes de operar o aparelho e conserve o mesmo para futuras referências ARWN100LA2 ARWN100DA2 ARWN200DA2 ARWN80BA2 ARWN160BA2 ARWN200LA2 ARWB100DA2 ARWB200DA2 ARWB80BA2 ARWB160BA2 TIPO Unidade Externa MODELOS PORTUGUESE ...

Page 14: ...ctrico ou incêndio Contacte o distribuidor ou um técnico autorizado para proceder à instalação do ar condicionado Uma instalação incorrecta feita pelo utilizador poderá resultar numa fuga de água choque eléctrico ou incêndio Ligue sempre o aparelho à terra Existe perigo de incêndio ou choque eléctrico Instale sempre um circuito e disjuntor exclusivos Uma instalação eléctrica incorrecta poderá prov...

Page 15: ...de oxigénio na divisão Não utilize o indicador múltiplo existente para o refrig erante R22 Utilize o indicador múltiplo para alta pressão R410A tanto quanto possível para um enchimento estável do refrigerante Não misture e utilize o tubo R22 e os aparelhos de instalação usados até agora A mistura do óleo do R22 e R410A pode provocar a avaria da unidade devido à hidrólise Não danifique nem utilize ...

Page 16: ...instala a unidade num hospital numa estação de comunicações ou num local similar dev erá prever se uma protecção adequada contra o ruído Equipamento inversor geradores privados equipamentos médicos de alta frequência ou equipamentos de comuni cações via rádio podem fazer com que o aparelho de ar condicionado funcione incorrectamente ou não funcione de todo Por outro lado o aparelho de ar condicion...

Page 17: ... interruptor ligado durante a época em que o aparelho é utilizado Não toque em nenhum tubo de refrigerante durante ou após o funcionamento Poderá provocar queimaduras ou ulcerações causadas pelo frio Não utilize o aparelho de ar condicionado com os painéis ou as protecções retiradas As peças giratórias quentes ou de alta tensão podem provocar ferimentos Não desligue o interruptor directamente depo...

Page 18: ...6 Unidade Exterior ...

Page 19: ......

Reviews: