WIRING CONNECTION
9
ENGLISH
Perform the electrical wiring work according
to the electrical wiring connection.
- All wiring must comply with local require-
ments.
- Select a power source that is capable of sup-
plying the current required by the air condi-
tioner.
- Use a recognized ELCB(Earth Leakage Cir-
cuit Breaker) between the power source and
the unit. A disconnection device to ade-
quately disconnect all supply lines must be
fitted.
- Model of circuit breaker recommended by
authorized personnel only
Outdoor
Indoor
Main
power source
Switch box
ELCB
Model
Phase
ELCB
ATUQ1 8GPLE6
1
20 A
ATUQ24GPLE6
APUQ24GS1A3
1
30 A
APUQ30GR5A3
1
30 A
ATUQ30LNLE6
3
20 A
ATUQ36GNLE6
APUQ36GR5A3
1
30 A
ATUQ36LNLE6
APUQ36LR5A3
3
20 A
ATUQ48GMLE6
APUQ48GT3E3
1
40 A
ATUQ48LMLE6
APUQ48LT3E3
3
20 A
Electrical Wiring
WIRING CONNECTION