INSTALLATION OF THERMOSTAT
ENGLISH
Installer Menu #
(Hold Menu 8
Seconds)
Description
Default Setting
(flashing icons)
Settings (Press
▲
or
▼
)
05
Outdoor Equipment: selects air
conditioner (AC) or heat pump
(HP) equipment as well as the
number of stage
AC2
AC0 AC1 AC2 HP1 HP2
10
Indoor Equipment: selects
whether the equipment is a
gas furnace, elec- tric furnace
or fan only
EL2
FAN GA1 GA2 EL1 EL2
15
Dedicated Emergency: W/E
only operates in Emergency
Aux mode. W2 becomes 1st
stage Aux. Heat
OFF
On OFF
20
O,B or 3 Wire Zone Valve
Selection
O
O B 3
30
Heat Cycle Rate: how often
the heat will turn on
MEd
SLO – slow
MEd – medium
FAS – fast
32
Aux Cycle Rate: how often the
auxiliary heat will turn on
MEd
SLO – slow
MEd – medium
FAS – fast
35
Cool Cycle Rate: how often the
cooling will turn on
MEd
SLO – slow
MEd – medium
FAS – fast
50
Compressor Lockout: protects
the compressor from short
cycling
OFF
On – 5 minute delay
OFF – no delay
65
Max Heat Limit: maximum set
point for heat mode
99
47 to 99
66
Minimum Cool Limit: minimum
set point for cool mode
45
45 to 97
79
Fahrenheit or Celsius
°F
°F – Fahrenheit
°C – Celsius
81
Temperature Display
Adjustment: adjust the displayed
“Room Temperature”
0
-5 to +5
83
Continuous Display Light: keep
the backlight always on – “C”
wire required
OFF
On – always on
OFF – momentarily
Installer Menu
To prevent changes that may affect system performance, this thermostat has an INSTALLER
MENU and a USER MENU.
The INSTALLER MENU provides access to every option, while the USER MENU provides access
to items that will not affect system performance.
To access the INSTALLER MENU press the Menu button for 8 seconds.
The display will show item 05 in the table below. Use Next and Back to navigate through menu
items. Press or to change a menu setting.