Wiring Connection
Wiring Connection
Electrical Wiring
Outdoor
Indoor
Main
power source
Switch box
ELCB
Perform the electrical wiring work according to the electrical wiring connection.
• All wiring must comply with local requirements.
• Select a power source that is capable of supply-
ing the current required by the air conditioner.
• Use a recognized ELCB(Electric Leakage Cir-
cuit Breaker) between the power source and
the unit. A disconnection device to adequately
disconnect all supply lines must be fitted.
• Model of circuit breaker recommended by
authorized personnel only
Installation Manual
9
Connecting Cables between Indoor Unit and Outdoor Unit
Outdoor
unit
Indoor
unit
1
2
3
1
2
3
Model
Phase(Ø)
ELCB
AUUQ18GH1
(ATUQ18GPLE3) (AVUQ18GJLA0) (ABUQ18GHLA0) (ABUQ18GL2A0)
1
20A
AUUQ21GH1
(ATUQ21GPLE3) (AVUQ21GJLA0) (ABUQ21GHLA0) (ABUQ21GL2A0)
1
AUUQ24GH1
(ATUQ24GNLE3) (AVUQ24GJLA0) (ABUQ24GGLA0) (ABUQ24GL3A0)
1
25A
AUUQ36GH1
(ATUQ36GMLE3) (AVUQ36GKLA0)(ABUQ36GGLA0)
1
30A
AUUQ42GH1
(ATUQ42GMLE3) (AVUQ42GLLA0) (ABUQ42GRLA0)
1
40A
AUUQ48GH1
(ATUQ48GMLE3) (AVUQ48GLLA0) (ABUQ48GRLA0)
1
AUUQ54GH1
(ATUQ54GMLE3) (AVUQ54GLLA0) (ABUQ54GRLA0)
1
Summary of Contents for ABUQ12GL2A0
Page 22: ...22 Air Conditioner ...
Page 23: ......