• Incorrect set of external static pressure may cause malfunction of the air conditioner.
• The external static pressure setting must be performed by qualified personnel.
This is a function to set wind speeds and volumes. This feature is to facilitate installation.
1
Pressing the
key and
key
simultaneously for more than 3 seconds can
enter the manual setting mode of the system.
- Select the code value of external static
pressure by pressing
key after entering
the manual setting mode.
* External static pressure value: 03
2
The
key can be used to select the required
wind speed. Press the
to set the [Very
Weak
→
Weak
→
Medium
→
Strong
→
Po]
wind speed in sequence and circularly.
3
Adjust the desired air volume with the
temperature adjustment buttons up (
) and
down (
).
* E.S.P range value: 0~255
- The static pressure value will be shown in
the display window.
4
Press the
key to save the E.S.P value
setting.
5
After the setting is completed, press the
key and
key simultaneously for more than
3 seconds to exit the manual setting mode of
system.
- If there is no key input within 25 seconds, the
system will also exit the manual setting
mode.
• The static pressure setting will change the air volume of the product, please be careful
when changing it.
• The static pressure value can be changed according to different products.
• Pressing wind speed button during the setting of static pressure value will not change static
pressure value of the wind speed.
Installer Setting - E.S.P Setting
ENGLISH
23
INSTALLATION INSTRUCTION