Installation
2. Art Cool Type Indoor Unit
The wall you select should be strong and solid enough
to prevent vibration
1) Open panel front
• First,Pull the grille bottom, then remove screws
(2 pieces), and close grille bottom again.
• The moment of lifting the both lower parts of panel
front, you can hear sound this panel came out, In
this time panel front is separated
• After pull down this panel a bit, and separate con-
necting wire with product.
2) Cover pipe and cover side remove
• Remove two screws(for fixing cover pipe)
• Pull up the cover side of desired connecting direc-
tion, then cover side is separated.
• In case connecting direction is left or right, path
through the hole of cover side.
NOTE:
When connecting pipe path through rear
wall, don’t remove the hole.
3) Drain hose junction
• Remove the rubber stopple of desired drain direc-
tion.
• As the following picture, Insert drain hose in the han-
dle of drain pan, and join drain hose and connecting
hose.
Panel Front
Connector
Pipe hole
CAUTION: After removing the pipe
hole, cut the burr for safety.