Installation
ø
8.5mm
GN/YL
20mm
ø
7.5mm
GN/YL
20mm
The power cord
connected to the outdoor unit
should be complied with the following specifica-
tions (Rubber insulation, type H05RN-F approved
by HAR or SAA).
The connecting cable
connected to the indoor
and outdoor unit should be complied with the fol-
lowing specifications (Rubber insulation, type
H07RN-F approved by HAR or SAA).
NORMAL CROSS-
SECTIONAL AREA
0.75mm
2
NORMAL CROSS-
SECTIONAL AREA
3.5mm
2
Air
Conditioner
Main power source
Circuit Breaker
Use a 30A circuit
breaker or time
delay fuse.
CAUTION: If a power plug is not to be used, provide a circuit breaker between
power source and the unit as shown below.
CAUTION