65
November 2009 50PQ30 Plasma
Diode Mode Readings taken with all connectors Disconnected. DVM in Diode Mode.
Y
Y
-
-
SUS P101 to Control P111 Plug Voltage Checks
SUS P101 to Control P111 Plug Voltage Checks
“Y-SUS" P101 CONNECTOR to “Control" P111
0.9V
0.11V
YSUS UP
29
0.9V
0.14V
ER UP
27
0.9V
2.6V
SUS DN
25
0.9V
0.114V
ER DN
23
0.9V
0.17V
Slope Rate Sel
21
0.9V
1.29V
Det Level Sel
19
0.9V
0.5V
Set On
17
0.9V
1.99V
Delta VY Det
15
Gnd
Gnd
Gnd
13
1.78V
0V
Gnd (Y Enable)
11
1.3
0.1V
CTRL_OE
9
2V
5V
5V
7
2V
5V
5V
5
1.37V
17.04V
15V
3
1.37V
17.04V
15V
1
Diode
Mode
Run
Label
Pin
Gnd
Gnd
Gnd
30
0.9V
1.1V
Blocking
28
0.9V
3.12V
Ramp Slope OPT 1
26
0.9V
024V
SET UP
24
0.9V
0.6V
CLK
22
0.9V
1.45V
STB
20
0.9V
1.44V
OC1
18
0.9V
0V
Data
16
0.9V
1.82V
OC2
14
Gnd
Gnd
Gnd
12
Gnd
Gnd
OE
10
Gnd
Gnd
Gnd
8
2V
4.95V
5V
6
2V
4.95V
5V
4
1.37V
17.04V
15V
2
Diode
Mode
Run
Label
Pin
There are No Stand By Voltages on this Connector
TIP: For Voltage readings,
Check Odd pins on Y-SUS board
Check Even pins on Control board