50
November 2009 50PQ30 Plasma
Observe the Picture while making these adjustments. Normally, they do not have to be done.
Set Up and Set Down Adjustments
Set Up and Set Down Adjustments
Y-Drive Test Point
ADJUSTMENT LOCATIONS:
Top Left and Center Right
SET-UP ADJUST:
1) Adjust
VR601
and set the
(A)
portion of the
signal to match the waveform above. (150V ± 5V)
SET-DN ADJUST:
2) Adjust
VR401
and set the
(B)
time of the
signal to match the waveform above. (100uSec 5uSec)
Set must be in “WHITE WASH”