52
November 2009 50PQ30 Plasma
All of the center washes out due to increased
SET_DN
time.
The center begins to wash out and arc due to decreased
SET DN
time.
Panel Waveform Adjustment
Set Down Adjustment Too High or Low
Set Down Adjustment Too High or Low
Set Dn
swing is Minimum 73uS Max 166uS+
NOTE: If Set DN too high, this set
may go excessive bright,
then shutdown.
If this happens, remove the LVDS
from Control board and make
necessary adjustments. Then
reconnect LVDS select White Wash
and adjust correctly.
(SET DN) Too High 166uSec
Full Clock Wise
(SET DN) Too Low
Counter Clock Wise
100V off
the Floor
Floor