19
300452480_002_C1 - 12/2017 - © Leybold
5
Maintenance
5.1 Safety Information
Observe all safety regulations.
All work must be done by suitably trained personnel. Maintenance or repairs
carried out incorrectly will affect the life and performance of the pump and
may cause problems when filling warranty claims.
Never mount used seals; always mount new seals.
5.2 Maintenance Intervals
The intervals stated in the maintenance schedule are approximate values for
normal pump operation. Unfavourable ambient conditions and/or aggressive
media may significantly reduce the maintenance intervals.
Maintenance job
Frequency
Section
Check the oil level
Daily
A
Oil changes operation
Annually
B
Longer with LVO700
Exhaust filter replacement
Annually
C
Longer with LVO700
Gas ballast valve
Monthly checking
D
Anti-suck back valve checking
Annually
E
Fan cover cleaning
Annually
F
Checking the float valve
Annually
G
In order to simplify the maintenance work we recommend to combine several
jobs.
Maintenance works must be carried out with proper tools in an adequate
work space / bench equipped with sufficient lighting.
Use only Leybold spare & consumables.
An overhaul at Leybold is recommended every 3 years.
After maintenance operations, make sure the device is in a safe condition
before putting back into operation.
Maintenance
Warning
Caution