PostScript
4-93
Enabled
boolean
(Read-only)
Supported values are:
True
False
Filtering
name
Indicates if the input needs further filtering before the data can be correctly processed.
Supported values are:
InterpreterBased
None
HasNames
boolean
(Read-only) Always returns False.
Interpreter
name (Read-only)
Supported values are:
PostScript
AutoSelect
PCL
PPDS
On
boolean
Designates if the communication channel is On and able to receive and send data.
Supported values are:
True
Data is sent and processed.
False
Data is lost.
PCLSmartSwitch
boolean
Supported values are:
True
PCL SmartSwitch is On.
False
PCL SmartSwitch is Off.
For more information, see “Using SmartSwitch” on page 2-1.
PortLocation
string
(Read-only) Designates the physical location of the port related to the parameter set.
Supported values are:
Standard Port
Option Slot 1
Option Slot 2
Option Slot 3
PSSmartSwitch
boolean
Supported values are:
True
PS SmartSwitch is set to On.
False
PS SmartSwitch is set to Off.
For more information, see “Using SmartSwitch” on page 4-1.
Type
name
(Read-only) Always returns the value of /Communications.
Device Parameters for the Communication Device %USB%, %USB_A%, %USB_B%, %USB_C%, %USB_D%
(%USB_NV% and %USB_Pending% contain the same parameters)
DelayedOutputClose
boolean
Selects how the printer manages the port at the end of each print job. Supported values are:
True
An end-of-file message is not sent until the current job and all preceding jobs
finish printing.
False
An end-of-file message is sent as soon as a job finishes executing in the
interpreter, whether or not that job has finished printing.
Table 4-17: PostScript Emulation Device Parameters (Continued)
Key
Type
Definition