PostScript
4-90
StopBits
integer
(Read-only)
Supported values are:
1
2
Type
name
(Read-only) Always returns the value of /Communications.
Device Parameters for the Communication Device %LocalTalk%, %LocalTalkA%, %LocalTalkB%, %LocalTalkC%,
%LocalTalkD%
(%LocalTalk_NV% and %LocalTalk_Pending% contain the same parameters)
DelayedOutputClose
boolean
Selects how the printer manages the port at the end of each print job. Supported values are:
True
An end-of-file message is not sent until the current job and all preceding jobs
finish printing.
False
An end-of-file message is sent as soon as a job finishes executing in the
interpreter, whether or not that job has finished printing.
This value is set independently for each port.
Enabled
boolean
(Read-only)
Supported values are:
True
False
Filtering
name
Indicates if the input needs further filtering before the data can be correctly processed.
Supported values are:
InterpreterBased
None
HasNames
boolean
(Read-only) Always returns False.
Interpreter
name (Read-only)
Supported values are:
PostScript
AutoSelect
PCL
PPDS
LocalTalkType
string
The “type” of the AppleTalk network entity name. This parameter also sets the Type
parameter to the same value. The new value is returned by the appletalktype compatibility
operator.
Legal value: Any string of 32 or fewer non-null characters. Default value is LaserWriter.
Note: Setting this variable does not affect the value for other physical internal print servers.
The statusdict string appletalktype is correct for the current job port.
NodeID
integer
(Read-only)
On
boolean
Designates if the communication channel is On and able to receive and send data.
Supported values are:
True
Data is sent and processed.
False
Data is lost.
Table 4-17: PostScript Emulation Device Parameters (Continued)
Key
Type
Definition