4. Press the Yes button once. The display reads: Devel DSP R Sw Nrm10. Verify that Mix is set to Loop 1.
5. Press the Yes button once. The display reads: Devel DSP L Sw Nrm10. Verify that Mix is set to Loop 1.
6. Press the Yes button once. The display reads: Devel Mix Switch. Verify that it is set to Off 0.
7. Press the Yes button 4 times. The display reads: Devel SpkSp. Verify that it is set to Byp 0.
8. Press the Yes button 4 times. The display reads: Devel SpkrSim.BP. Verify that Mix is set to Byp 0.
1. Set the Analyzer to measure THD+N.
2. Verify the output level readings for each of the input level settings in the table below.
Levels
Upper
Lower
(Vrms)
%
%
-15dBu (.14)
1.56
0.14
-14dBu (.15)
4.14
0.76
-13dBu (.17)
6.96
1.71
-12dBu (.19)
9.54
2.65
-11dBu (.21)
11.71
3.47
3. Move the cable from the Left Insert Return jack to the Right Insert Return jack.
4. Move the cable from the Left Main Output jack to the Right Main Output Jack.
5. Verify the output level readings for each of the input level settings in the table below.
Levels
Upper
Lower
(Vrms)
%
%
-15dBu (.14)
1.56
0.14
-14dBu (.15)
4.14
0.76
-13dBu (.17)
6.96
1.71
-12dBu (.19)
9.54
2.65
-11dBu (.21)
11.71
3.47
6. Set the Analyzer back to measure level.
7. At this time, in order to continue you will want to turn the Soft Sat back 0ff and reset the MPX G2 as
described at the top of this test.
THD+N Measurement – Soft Sat OFF:
1. Apply a 1kHz-sinewave signal at -14dBu (155 mVRMS).
2. Set the Analyzer to measure THD+N.
3. Verify an output THD+N reading is between (0.01 to 0.0007%) at the following frequency settings.
20,000Hz
15,000Hz
10,000Hz
5,000Hz
3,000Hz
997Hz
100Hz
20Hz
4. Move the cable from the Right Insert Return jack to the Left Insert Return jack.
5. Move the cable from the Right Main Output jack to the Left Main Output Jack.
6. Verify an output THD+N reading is between (0.01 to 0.0007%) at the following frequency settings.
20,000Hz
15,000Hz
10,000Hz
5,000Hz
3,000Hz
997Hz
100Hz
20Hz
7. Set the Analyzer back to measure level.
Signal To Noise Ratio:
1. Apply a 1kHz-sinewave signal at -10dBu (245 mVRMS).
2. Set the Analyzer for a 0dB reference (@ 1kHz).
Summary of Contents for MPX G2
Page 1: ...MPX G2 Guitar Effects Processor Service Manual ...
Page 8: ......
Page 10: ......
Page 12: ......
Page 104: ......
Page 106: ......
Page 107: ...8 3 ...
Page 108: ...8 4 Your Notes ...
Page 109: ...8 5 ...
Page 110: ...8 6 Your Notes ...
Page 111: ...8 7 ...
Page 112: ...8 8 Your Notes ...
Page 113: ...8 9 ...
Page 114: ...8 10 Your Notes ...
Page 115: ...8 11 ...
Page 116: ...8 12 Your Notes ...
Page 117: ...8 13 ...
Page 118: ...8 14 Your Notes ...
Page 119: ...8 15 ...
Page 120: ...8 16 Your Notes ...
Page 121: ...8 17 ...
Page 122: ...8 18 Your Notes ...
Page 123: ...8 19 ...
Page 124: ...8 20 Your Notes ...
Page 125: ...8 21 ...
Page 126: ...8 22 Your Notes ...
Page 127: ...8 23 ...
Page 128: ...8 24 Your Notes ...
Page 129: ...8 25 ...
Page 130: ...8 26 Your Notes ...
Page 131: ...8 27 ...
Page 132: ...8 28 Your Notes ...
Page 133: ...8 29 ...
Page 134: ...8 30 Your Notes ...
Page 135: ...8 31 ...
Page 136: ...8 32 Your Notes ...
Page 137: ...8 33 ...
Page 138: ...8 34 Your Notes ...
Page 139: ...8 35 ...
Page 140: ...8 36 Your Notes ...
Page 141: ...8 37 ...
Page 142: ...8 38 Your Notes ...
Page 143: ...8 39 ...
Page 144: ...8 40 Your Notes ...
Page 145: ...8 41 ...
Page 146: ...8 42 Your Notes ...
Page 147: ...8 43 ...
Page 148: ...8 44 Your Notes ...
Page 149: ...8 45 ...
Page 150: ...8 46 Your Notes ...
Page 151: ...8 47 ...
Page 152: ...8 48 Your Notes ...
Page 153: ...8 49 ...
Page 154: ...8 50 Your Notes ...
Page 155: ...8 51 ...
Page 156: ...8 52 Your Notes ...
Page 157: ...8 53 ...
Page 158: ...8 54 Your Notes ...
Page 159: ...8 55 ...
Page 160: ...8 56 Your Notes ...
Page 161: ...8 57 ...
Page 162: ...8 58 Your Notes ...
Page 163: ...8 59 ...
Page 164: ......