Lexicon, Inc.
MC-12 Serial Communications Protocol
Printed on: 08/18/03
© 2003 Lexicon, Inc. All rights reserved.
44 of 94
Data Type:
Null (0x00) terminated ASCII string.
Max Length:
21 (20 characters plus terminating Null)
7.3.44 MC-12 Clear All Parameter Notifications (MC-12)
Request to the MC-12 to disable all MC-12 parameter notifications.
7.3.44.1 Command Packet Description
Application Header:
Command
MC_CMD_CLEAR_ALL_PARAM_NOTIFICATIONS 0x3D
Data Count
0
0x00
Application Data:
N/A
7.3.45 MC-12 Get System Status (MC-12)
Request to MC-12 for its current system status. MC-12 will respond with “System Status Packet”.
7.3.45.1 Command Packet Description
Application Header:
Command MC_CMD_GET_SYS_STATUS
0x3E
Data Count 0
0x00
Application Data:
N/A
7.3.45.2 System Status Response Packet
Application Header:
Command MC_RESP_SYS_STATUS 0x94
Data Count 10
0x0A
Application Data:
Data[0]
System Volume
nn
Data[1]
Current Input
nn
Data[2]
Current Effect Id
nn
Data[3]
Current Input Sample Rate nn
Data[4]
Current Input Format
nn
Data[5]
Mute Active
nn
Data[6]
Effect Bypass
nn
Data[7]
Left/Right Balance
nn
Data[8]
Front/Back Balance
nn
Data[9]
Video Sync
nn
7.3.45.3 Data Description
System Volume: