background image

8

CT AMPERAGE RATINGS AND TENANT INFORMATION CHART

S8000  

Model 

Number

1

Element

(CT)

Meter

Mode

2

Element

(CT)

Meter

Mode

3

Element

(CT)

Meter

Mode

Connect

X1 CT 

lead

(white)

to X1

input

color

Connect

X2 CT 

lead

(black)

to X2

input

color

CT

Amperage

Circuit

Number

Description

(Dwelling/Apt/Unit #)

Cable 1

P1-1

P1-1

P1-1

1

Black

Green

P2-1

P1-2

P1-2

2

Black

White

P3-1

P2-1

P1-3

3

Black

Red

P4-1

P2-2

P2-1

4

Red

Green

P5-1

P3-1

P2-2

5

Red

White

P6-1

P3-2

P2-3

6

Black

Orange

P7-1

P4-1

P3-1

7

Black

Brown

P8-1

P4-2

P3-2

8

Black

Y

ellow

P9-1

P5-1

P3-3

9

Black

Blue

P10-1

P5-2

P4-1

10

Green

Y

ellow

P1

1-1

P6-1

P4-2

11

Green

Blue

P12-1

P6-2

P4-3

12

Green

White

P13-1

P7-1

P5-1

13

Blue

White

P14-1

P7-2

P5-2

14

Green

Orange

P15-1

P8-1

P5-3

15

Green

Brown

P16-1

P8-2

P6-1

16

Blue

Y

ellow

P17-1

P9-1

P6-2

17

Brown

White

P18-1

P9-2

P6-3

18

Orange

White

P19-1

P10-1

P7-1

19

Red

Orange

P20-1

P10-2

P7-2

20

Red

Y

ellow

P21-1

P1

1-1

P7-3

21

Red

Brown

P22-1

P1

1-2

P8-1

22

Blue

Orange

P23-1

P12-1

P8-2

23

Y

ellow

White

P24-1

P12-2

P8-3

24

Blue

Brown

8124 - S8120-122, S8UWH-083, S8UWH-122, S8UWH-241

8118 - S8120-092

8112 - S8120-062

8106 - S8120-032

Termination
Module CT #

WEB 

VERSION

Summary of Contents for VerifEye

Page 1: ...PK A3236 10 00 0A Series 8000 Meter For use with catalog numbers S8120 S8UWH 277TS Quick Start Guide VerifEye WEB VERSION...

Page 2: ...WEB VERSION...

Page 3: ...ction 3 Wiring Diagrams 5 Split Phase 120 240 VAC 1P 3W 5 3 Phase Wye 120 208 VAC 3P 4W 5 1 Phase 120 VAC 1P 2W 5 1 Phase Wye 277 VAC 1P 2W 5 3 Phase Wye 277 480 VAC 3P 4W 5 Section 4 Installing Curre...

Page 4: ...nect must be provided such as a breaker from the panel that will allow shut off of power to the meter for servicing Voltage references to the meter should be connected to a circuit breaker in the pane...

Page 5: ...s 8000 multi circuit meter Indicated in the diagram are the names of the speci c components of the meter which will be referred to later in this guide Follow the installation steps below for the appro...

Page 6: ...nel please refer to the full manual for additional types Now use the appropriate diagram on the following page for attaching the voltage references depending on the panel feed For 120 208 240 VAC serv...

Page 7: ...VAC 3P 4W Split Phase 120 240 VAC 1P 3W 3 Phase Wye 120 208 VAC 3P 4W J3 J18 AUXNAUXA White Black C B A N J3 J18 AUXNAUXA C B A N Brown White A N Red Black White J3 J18 AUXNAUXA C B A N Red Black Whit...

Page 8: ...should face the source Example of a solid core CT Orientation is based on the product label indicating which side should face the source Use the appropriate diagram below to identify the correct orie...

Page 9: ...hat are to be matched with the corresponding CTs from the panel Please refer to the spreadsheet on the last page of the quick start guide which cross lists the twisted pair wiring colors to the input...

Page 10: ...1 P3 1 7 Black Brown P8 1 P4 2 P3 2 8 Black Yellow P9 1 P5 1 P3 3 9 Black Blue P10 1 P5 2 P4 1 10 Green Yellow P11 1 P6 1 P4 2 11 Green Blue P12 1 P6 2 P4 3 12 Green White P13 1 P7 1 P5 1 13 Blue Whit...

Page 11: ...WEB VERSION...

Page 12: ...ponsorship or endorsement Leviton Energy Management Controls and Automation 20497 SW Teton Avenue Tualatin OR 97062 Customer Service Telephone 1 800 736 6682 FAX 1 503 404 5600 Tech Line 1 800 959 600...

Reviews: