background image

PK-A3218-10-00-0B

For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) 

1 800 405-5320 (Canada Only) www.leviton.com

PK-A3218-10-00-0B

INSTALLATION INSTRUCTIONS

Nos. 

LP3xx-MC, LP4xx-MC

© 2018 Leviton Mfg. Co., Inc.

Outdoor Meter - Load Center Combination Enclosure

INSTALLATION

WARNING: TO AVOID FIRE, SHOCK OR 

DEATH: TURN OFF POWER SUPPLYING 

THIS EQUIPMENT, AND CONFIRM POWER 

IS OFF,

 before installing, removing or 

servicing this equipment.

Step 1:  Remove meter and wiring 

compartment covers 

(fig. 1)

a.

  Remove 

Meter cover (B)

 by loosening 

the 

securing screw (J)

 and sliding cover 

down and out. 

b.

  Remove 

wiring compartment cover (C)

 

by loosening the 

securing screw (K)

 and 

sliding 

security latch (A)

 upward and 

sliding cover out and down.

c.

  Slide 

wiring compartment cover (C)

 

up and out.

Step 2: Remove Load Center Door 

(Optional)

NOTE: 

The load center door can be removed for 

easier installation.

a.

  Lift 

door (D)

 upward to remove from 

hinge (E) 

(fig. 2)

b.

  When installation is complete, align the 

door 

hinge (E)

 with the hinge pin and insert 

downward until door is seated.

Step 3: Bottom Feed Wiring

NOTE: 

Before removing any knockouts from the 

enclosure, consult the local electrical code to 
determine the knockout requirements.

a.

  To remove 

knockouts (F)

, first strike the center 

of the knockout.

b.

  Pry each 

ring (G)

 up, one at a time, and grip 

both ends with a pair of pliers.

c.

  Use the pliers to bend the 

rings (G)

 until they 

disconnect from the enclosure 

(fig. 3)

.

Step 4: Enclosure Mounting

Surface Mounting

a.

  Remove 

deadfront (S)

 by loosening the 

securing 

screw (T)

 and lifting the 

deadfront (S)

 off the 

enclsoure.

b.

  Remove 

mounting knockouts (H)

 from the back 

of the enclosure 

(fig. 4).

c.

  Use outdoor approved screws or nails (not 

provided) in the 

mounting knockouts (H)

 to 

secure the enclosure to the wall.

Fig. 1

Fig. 3

Fig. 2

Fig. 4

a.

b.

c.

IMPORTANT SAFETY INSTRUCTIONS - 

READ ALL INSTRUCTIONS BEFORE USING.

PATENTS PENDING

LIMITED PRODUCT WARRANTY

For Leviton’s limited product warranty, go to 

www.leviton.com

. For a printed copy of the warranty you may call 

1-800-323-8920

.

WARNING

•  

TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER SUPPLYING THIS EQUIPMENT, AND CONFIRM POWER IS OFF,

  

before installing, removing or servicing this equipment.

•  This equipment 

MUST BE

 installed and serviced by an electrician.

•  Replace all doors and covers before connecting power to this equipment.
•  To be installed and/or used in accordance with electrical codes and regulations.

Knockout

(F)

Ring

(G)

Ring

(E)

Mounting

Knockouts

(H)

Down

Meter
cover
(B)

Wiring

compartment

cover

(C)

Down

Out

Out

Hinge pin

Hinge (E)

Door (D)

Securing

latch (A)

Screw

(K)

Screw

(J)

Meter cover (B)

Wiring

compartment

cover (C)

WEB 

VERSION

Reviews: