background image

InTANK

iR8022

User Manual

Summary of Contents for InTANK Series

Page 1: ...InTANK iR8022 User Manual ...

Page 2: ...cedure 3 5 RAID Mode Setting 4 6 Computer Setup 5 7 Hard Disk Status on LCD Screen 6 8 Data Rebuilding Operation 7 9 GUI Monitoring Software and Firmware Update 8 10 Questions Answers 10 InTANK iR8022 產品使用說明 12 1 產品外觀及包裝內容 12 2 環境需求 13 3 硬體需求與注意事項 13 4 硬體安裝 14 5 設定 RAID 層級 15 6 電腦設定 16 7 訊息顯示 17 8 資料重建功能說明 18 9 GUI 功能說明與韌體更新 19 10 常見問題 21 iR8022 User Manual V1 0 ...

Page 3: ...t is subjected to change without prior notifications If you have any question regarding to the product you purchased or you would like to know the latest product information User Manual s update please contact to your local supplier or visit to www raidon com tw for further information Copyright Raidon Technology Inc All right is reserved Open the package and you should find the following parts iR...

Page 4: ...ccessing Data Solid Blue Flashing Blue Purple Rebuilding Source Solid Blue Solid Blue Rebuilding Target Solid Blue Flashing Red 6 Power False Indicator 7 Removable Drive Tray 8 HDD Tray Key Lock And Tray Open Button 9 HDD Status Indicator 2 Operation Information Operating Temperature 5 35 41 95 Storage Temperature 10 70 o C 14 158 o F Line Voltage 5V DC 3 Hardware Requirements and Precautions 1 Co...

Page 5: ...tep 10 Install M 2 SATA Bridge in a Tray Step 11 Fix the screws Step 12 Install the M 2 SATA Bridge tray back into the iR8022 4 iR8022 product allows user to simultaneously use the two different hard drives from two different manufactures However if the user expects a better efficiency we strongly recommend the user to use the two hard drives from the same manufacturer 5 Please make sure that the tw...

Page 6: ... two hard drives failed iR8022 will still work fine and properly Once you replace the failed hard disk with a new one iR8022 will automatically do rebuilding the data from the good one to the new hard disk Step 13 When the hard drive installation has been completed insert the hard drive tray into the system horizontally and secure the latch into place Step 14 Use the preferred cable included to co...

Page 7: ...mpletely finished The user can freely retrieve and save data to iR8022 just like retrieving and saving data to a regular hard drive If the user has any problem during the operation please refer to the Question Answer Q A section in Appendix 2 RAID 0 mode 1 Place two new hard drives into iR8022 We would strongly suggest you to use two identical hard drives to get the maximum memory capacity And if ...

Page 8: ... is normal RAID 1 degraded Pri X Sec O 5 RAID 1 Failure Primary and secondary hard drives are failure RAID 1 failure Pri X Sec X 6 RAID 1 Failure Double Source RAID 1 failure Double Source 7 RAID 0 Failure Primary hard drive is missing but secondary hard drive is normal RAID 0 failure Pri M Sec O 8 Rebuilding Rebuilding Sec Pri 32 1 Booting and Normal status iR8022 RAID 1 vxxxxxx x Pri HDD OK Sec ...

Page 9: ...n remove the failed hard drive from the system while the system is still in operation without shutting down the machine If the failed hard drive is replaced shortly the system will automatically execute the Auto Rebuilding function without affecting the system operation and also any operation command from the user When the iR8022 detects one hard drive missing or failure the Buzzer starts BEEPING ...

Page 10: ...gly 2 Firmware Upfrade You may update the Firmware via this GUI to just simply click on the Load button to locate the firmware file to proceed After completing the update you may restart the power to work with the new firmware Caution Any random firmware update may cause the malfunction at your iR8022 We strongly recommend you not to change upgrade iR8022 firmware if still works properly 9 GUI Mon...

Page 11: ... completing the configuration click on the OK button to save Device must be in the operation states during configuration works 3 2 HDD Failure Device Removed 1 Insert your e mail address as the receiver for notification and click on to add the e mail address onto the Notification List Maximum up to 10 e mail addresses 2 Key in the Subject title and contents in the columns of Subject and Contents 3...

Page 12: ...orting raidon com tw Computer works fine but iR8022 doesn t perform right in reading writing messagesproperly Please first check whether if iR8022 is executing the auto REBUILDING work If it works for REBUILDING your iR8022 is a good device And if it doesn t please follow the following two ways to find out the possible root cause 1 Please examine if your SATA cable is too long and will attenuate s...

Page 13: ...ll happen if we turn off the computer power while iR8022 is still executing auto REBUILDING work Under the Mirror mode RAID 1 if computer power is off during REBUILDING work iR8022 will still remember the percentage of its REBUILDING work and then resume it back to its REBUILDING work while computer power is back on Is it possible to lose data during the REBUILDING work The REBUILDING work will au...

Page 14: ...貨時為準 任何產品規格或相關資訊更新請您直接到 www raidon com tw 網站查詢 本公司將不另行通知 若您 想獲得 RAIDON 最新產品訊息 使用手冊 韌體或對 RAIDON 產品有任何疑問 請您聯絡當地供應 商或到 www raidon com tw 取得相關訊息 本手冊相關產品內容歸銳銨科技股份有限公司版權所有 打開包裝外盒後 包裝內容應包含下列組件 iR8022 iR8022 產品本體 x1 內含抽取盒 x2 SATA 線 x1 螺絲及鑰匙 快速安裝導引 x1 InTANK iR8022 產品使用說明 請確認相關配件與產品本身是否有受損或配件缺少 若有任何疑問請與本產品供應商聯絡 請前往官網 www raidon com tw 下載驅動程式以及其餘相關資源 ...

Page 15: ...0 C 紫燈恆亮 鳴叫 硬碟故障 紫燈恆亮 紅燈恆亮 鳴叫 待機 藍燈恆亮 藍燈恆亮 格式化 資料存取 藍燈恆亮 藍紫燈交互閃爍 Rebuilding Source 藍燈恆亮 藍燈恆亮 Rebuilding Traget 藍燈恆亮 紅燈閃爍 6 電源 故障顯示燈 7 硬碟托盤把手 8 硬碟卡榫按鈕 9 硬碟讀寫燈 2 環境需求 工作溫度 5 35 41 95 儲存溫度 10 70 o C 14 158 o F 工作電壓 5V DC 3 硬體需求與注意事項 1 電腦或伺服器具備 SATA I SATA II 或 SATA III 介面 2 具備 SATA I SATA II 或 SATA III 介面的硬碟 3 強烈建議使用 iR8022 前先設定好 RAID 模式 預設值是 RAID 1 4 本系統允許使用不同廠牌的硬碟 但如果要獲得更好的效能 我們強烈建議使用相同廠牌型號的硬碟 ...

Page 16: ...式確認後 使用相同的硬碟進行模式切換將會導致資料遺失 如果需要進行模 式變更 請於變更前先進行資料備份 4 硬體安裝 請參照以下步驟完成硬體安裝 Unlock Lock 1 2 3 4 5 6 7 8 9 10 11 12 步驟 1 請使用零件包內附的鑰匙插入鑰匙孔向左轉 90 度 步驟 2 輕按鎖頭抽取盒門閂將會輕彈開啟 步驟 3 將 M 2 SATA Bridge 抽取盒取出 步驟 4 M 2 SATA Bridge 抽取盒兩側的螺絲取出 步驟 5 把 M 2 SATA Bridge 由抽取盒取出 步驟 6 取下 M 2 SATA Bridge 上蓋螺絲 打開上蓋 步驟 7 插入 M 2 並鎖上螺絲 步驟 8 撕下上蓋裡散熱片的離型紙 蓋回上蓋 步驟 9 鎖上上蓋螺絲 步驟 10 將 M 2 SATA Bridge 放進抽取盒 步驟 11 鎖上兩側螺絲 步驟 12 將 M 2 SATA...

Page 17: ...容量 如果 兩顆硬碟的容量不同 iR8022 將會以小容量的硬碟為依據 2 RAID 1 模式下 兩顆硬碟是鏡射關係因此擁有相同的資料 因此有一顆硬碟損毀仍然可以正常運 作 當放入新硬碟取代損毀硬碟後 系統會自動將資料重建到新的硬碟 2 RAID 0 模式 1 將新的硬碟放入 iR8022 中 強烈建議您使用兩顆相同的硬碟 以便取得對等的容量 如果兩顆 硬碟的容量不同 iR8022 將會以小容量的硬碟為依據 2 RAID 0 模式下 兩顆硬碟的容量會被加總成一個大儲存容量 並且提供更佳的存取效能 Note 1 RS232 埠與 RS232 線 提供工控系統或是工業電腦透過 RS232 監控硬碟狀態 2 我們不建議使用者在未經授權的情況下自行拆卸系統 如未經授權自行拆卸所導致的損毀將不在保固之列 3 為了防止系統發生問題 請確保系統的電源供應是穩定且獨立的 4 RS232 連接埠和 RS23...

Page 18: ...設定 當 iR8022 的硬體安裝完成 即可準備進行開機動作 硬體安裝完成後 將 BIOS 的硬碟偵測設定為自動 iR8022 將會被視為如同一顆硬碟一般 當電腦開 機後 系統會顯示下列偵測訊息 1 安裝在 iR8022 中的硬碟能夠被 Windows 的裝置管理員偵測到 2 使用 iR8022 前 使用者可以透過磁碟管理選擇硬碟的格式 到此完成整個安裝程序 使用者可以如同存取一般硬碟般的使用 iR8022 如果使用上仍有問題 請參 閱附件的 Q A ...

Page 19: ...級 Pri 硬碟損毀而 Sec 硬碟仍然可正常存取 RAID 1 degraded Pri X Sec O 5 RAID 1 損毀 Pri 與 Sec 硬碟皆損毀 RAID 1 failure Pri X Sec X 6 RAID 1 損毀 Source 碟重複 RAID 1 failure Double Source 7 RAID 0 損毀 Pri 硬碟遺失而 Sec 硬碟仍然正常 RAID 0 failure Pri M Sec O 8 資料重建 Rebuilding Sec Pri 32 1 開機與正常待機狀態 iR8022 RAID 1 vxxxxxx x Pri HDD OK Sec HDD OK ...

Page 20: ...CD 顯示幕與監控軟體發出警示 使用者可以在系統 仍在運作下 無需關掉機機器即可將損毀的硬碟取出 一但替換損毀硬碟後 iR8022 即會在不影響系 統運作的情況下自動開始進行資料重建 使用者也無需對 iR8022 下任何指令 當 iR8022 偵測到硬碟遺失或是損毀 蜂鳴器會啟動 LCD 螢幕會顯示以下訊息 當移除損毀的硬碟並替換一顆新硬碟後 如果新硬碟有正確安裝 LCD 螢幕會顯示以下訊息 安裝新硬碟後幾秒鐘 LCD 螢幕會顯示資料重建的進度 當資料重建完成後 LCD 螢幕會顯示以下訊息 8 資料重建功能說明 Pri HDD OK Sec HDD OK RAID 1 degraded Pri X Sec O Pri HDD OK Sec HDD Insert Rebuilding Sec Pri 32 Pri HDD Insert Sec HDD OK Rebuilding Pri Se...

Page 21: ...ual 19 使用者可以透過光碟來安裝 GUI 軟體 藉此監控 iR8022 的狀態 1 系統狀態 GUI 會自動偵測 iR8022 並且顯示相關資訊 2 韌體升級 使用者可以透過此 GUI 進行韌體升級 只需簡單的點選 Load 指定韌體檔案位置後即可進行升級 升級過程或許需要重新啟動系統來完成整個升級程序 注意 任意更新韌體有可能導致系統運作不正常 強烈建議如果系統運作正常情況下不要進行韌體升級 9 GUI 功能說明與韌體更新 ...

Page 22: ... mail 相關名稱與完整位置 以及 SMTP 的相關資訊 2 如果需要密碼 請勾選 SMTP Login Authentication 並輸入密碼 3 相關資訊填寫完成後 點選 OK 設定過程中 系統必須維持在正常運作狀態 3 2 硬碟損毀 裝置被移除 1 在 E Mail Address 欄位填入要收取通知的 e mail 點選 即可增加另一組 最多可填 入 10 組 e mail 2 在 Subject 與 Contents 填入 e mail 訊息的主旨與內容 3 相關資訊填寫完成後 點選 OK 設定過程中 系統必須維持在正常運作狀態 ...

Page 23: ...還是無法正常開機 這有可能是因為硬體上的相容性問題 如果是硬體 上相容性問題 請連繫我們的客服部門 使用時 電腦運作正常但是 iR8022 的存取效能不正常 請確認 iR8022 是否正在資料重建 1 請確認所使用的連接線長度 是否所使用的 SATA 線太長以及是否合乎標準規範 2 如果線材的長度與規格都沒問題 請關閉 iR8022 並取出其中的硬碟 直接接硬碟連接到電腦 並進行檢測 有可能是硬碟中的壞軌導致 RAID 1 模式下 如果放入一顆新的硬碟 系統的總容量會是 1 iR8022 的總容量是依據一開始安裝的主硬碟容量而定 2 安裝完成後 即使更換一顆較大容量的硬碟 儲存容量也不會增加 為何當我安裝第二顆硬碟時出現錯誤訊息 第二顆硬碟的容量必須大於第一顆硬碟 否則 iR8022 不會進行資料重建 10 常見問題 Q1 A Q2 A ...

Page 24: ...重建時關掉電腦電源 會不會怎樣 在 RAID 1 模式下資料重建過程中關閉電源 控制器會自動記憶已完成的百分比 當再度開啟電 源後 重建過程會從斷電前的百分比繼續 資料重建過程中是否有可能會遺失資料 資料重建功能是 Sector to Sector 的拷貝方式 技術上來說 資料並不會在資料重建過程中遺失 但是 如果資料重建過程中 原本的硬碟 Source 被偵測到壞軌 iR8022 將會採用模擬方式而 不會因此壞軌認為硬碟損毀 因此 這種情況下儲存在壞軌的資料就有可能會遺失 Q1 A Q2 A ...

Page 25: ...iR8022 User Manual 23 www raidon com tw ...

Reviews: