INSTALLATION AND OPERATING INSTRUCTIONS
ENGLISH
WARNINGS AND CAUTIONS
•
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER
at circuit breaker or fuse and
test that power is off before wiring!
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult an electrician.
WARNINGS AND CAUTIONS
• This product must be installed in a suitable junction box or equivalent enclosure.
• Use this device with
copper or copper-clad wire only.
• For indoor use only.
• SAVE THESE INSTRUCTIONS.
LEVITON UPB™ 15A RELAY SWITCH AND AUXILIARY SWITCH
Cat. No. 40A00-1
Installation Instructions and User’s Guide
DI-022-HL401-05A
AR2253
(40I00-1)
For the following Models:
40A00-1 Leviton 15A Relay Switch (referred to as Leviton UPB™ Wall Switch, in this document),
and 37A00-1 Leviton Auxiliary Switch.
NOTE:
All Leviton UPB™ Wall Switches require a neutral (white) connection wire.
Leviton UPB™ Wall Switch Overview
The Leviton UPB™ Wall Switch
(Figure 1)
allows for local control of loads by using the rocker switch. It also
incorporates the UPB™ two-way powerline communication technology that gives it the ability to be remotely
controlled by UPB™ compatible controllers. The Leviton UPB™ Wall Switch is also capable of transmitting
UPB™ messages when the rocker switch is turned on or turned off.
The Leviton 15A Relay Switch is used to control loads such as receptacles, motor-operated appliances (i.e.
fans), and fluorescent lighting fixtures.
Figure 1 - Leviton UPB™ Wall Switch
(ON/BRIGHT)
(OFF/DIM)
BOTTOM
LED
INDICATOR
TOP
GROUND
GREEN
RED
YELLOW
WHITE
LOAD
CONTROL
NEUTRAL
BLACK
LINE
Leviton Auxiliary Switch Overview
The 37A00-1 Leviton Auxiliary Switch
(Figure 2)
is an optional companion device used with the Leviton UPB™
Wall Switch for multi-way circuits. The Leviton Auxiliary Switch has a rocker switch that controls the load in the
exact same manner as the rocker switch on the Leviton UPB™ Wall Switch.
Figure 2 – Leviton Auxiliary Switch
YELLOW
BLUE
GRAY
CONTROL
*NEUTRAL
*NEUTRAL
BLACK
LINE
BOTTOM
(OFF/DIM)
(ON/BRIGHT)
TOP
(FOR RED INDICATOR)
(FOR BLUE INDICATOR)
INDICATOR
LED
Changing Switch Color
The color of the Leviton UPB™ Wall Switch and Auxiliary Switch may be changed to complement the interior
décor. The Leviton UPB™ Wall Switch and Auxiliary Switch is supplied with a white switch plate. Additional
colors are available; contact your Leviton distributor for more information. When changing the switch plate,
make sure that the switch is disconnected from all power, and proceed as follows:
Figure 3 – Changing Switch Color
1.
The switch plate attaches to the Leviton UPB™ Wall Switch and Auxiliary Switch with two
latches on the right and two on the left. Using a small-bladed screwdriver, gently depress the
upper and lower latch on one side while lifting up on the plate. Once the latches are released
on one side, remove the switch plate from the other side.
2.
Align the latches of the new switch plate to the openings on the mounting plate and gently
snap into place.
INSTALLATION INSTRUCTIONS
The Leviton UPB™ Wall Switch is wired directly to the load and can be controlled by adding one
or more optional Leviton Auxiliary Switches producing multi-way circuits. Multi-way circuits make
it possible for a group of switches to control the same load. This section will illustrate how to
make the connections.
NOTES:
1.
Refer to
Figures 1 and 2
to determine the wire colors for each connection.
2.
All Leviton UPB™ Wall Switches require a neutral (white) connection.
3.
The Line (black) wire must be accessible for the installation of all Leviton Auxiliary Switches.
This wire may be connected to either phase of the 120/240V supply. The blue and/or gray
wire on the Leviton Auxiliary Switch can be connected to either earth ground or neutral. The
blue and/or gray wire is only used to light the LED on the switch. This LED only indicates that
power is applied and serves as a night-light. Connect the blue wire only to light the LED blue.
Connect the gray wire only to light the LED red. Connect both the blue wire and the gray wire
to light the LED magenta.
Installation Procedure
1.
Be sure that all power to the load has been disconnected by turning off the circuit breaker.
2.
If applicable, remove the faceplate from the existing wall switch, remove the existing wall switch from the wall box, and
disconnect the wires from the existing wall switch. Identify the "Line", "Neutral", "Load" and "Traveler" (if applicable) wires.
3.
Remove 3/4" of insulation from each of the wires on the Leviton UPB™ Wall Switch. Install the Leviton UPB™ Wall Switch
by connecting wires per wiring configuration shown in
Figure 5
.
4.
Install any optional Leviton Auxiliary Switch per wiring configuration shown in
Figure 5
.
6.
After all connections have been made, be certain that all wire connectors are firmly attached and there is no exposed copper.
5.
Gently place the wires and Leviton UPB™ Wall Switch into the wall box with the LED at the top of device. Using the supplied
screws, attach the Leviton UPB™ Wall Switch to the wall box.
6.
Before installing the faceplate, restore power to the circuit, and then fully close the air-gap switch lever.
7.
After testing the Leviton UPB™ Wall Switch and Auxiliary Switch for proper local operation
(see Table 1)
,
install a Decora
®
faceplate over each switch.
Leviton 15A RELAY SWITCH OPERATION
The Leviton 15A Relay Switch has configurable items that can be set using the UPB™ UPStart configuration software. The
following describes the operation of the Leviton 15A Relay Switch in its factory default configuration.
Local Rocker Switch Operation
The Leviton 15A Relay Switch has a rocker switch that can be used to control the load as follows.