Table 1 - Leviton UPB™ 15A Relay Switch Local Operation

Rocker Event

Top Rocker

Bottom Rocker

Single-Tap

Load turns on.

Load turns off.

Leviton AUXILIARY SWITCH OPERATION

The Leviton UPB™ Wall Switch can be connected to 

one or more Leviton Auxiliary Switches producing multi-

way circuits. Each Leviton Auxiliary Switch has a rocker 

switch that controls the load in the exact same manner 

as the rocker switch on the connected Leviton UPB™ 

Wall Switch, as previously described. When connected, 

the LED remains continually on at all times while power 

is applied.

LED Indicator

The Leviton UPB™ Wall Switch comes equipped with 

a multi-color LED indicator that is normally lit to blue 

when the load is off.  The LED is off when the load is 

on.
If used, the LED in the Leviton Auxiliary Switch is 

always lit.

Setup Mode

To configure the Leviton UPB™ Wall Switch using an 

Leviton controller or a PC running the UPB™ UPStart 

configuration software, it must be put into Setup Mode 

as follows:

Step

Operation

1

Tap the rocker switch quickly 5 times.

2

The Leviton UPB™ Wall Switch will cycle the load one time and blink its LED blue to indicate that it is in 

Setup Mode. 

NOTE:

 the switch will automatically exit Setup mode after 5 minutes.

Figure 4 - Wiring Diagram

LINE

NEUTRAL

37A00 (OPTIONAL)

AUXILIARY SWITCH

AUXILIARY SWITCH

37A00 (OPTIONAL)

40A00

HAI Relay Switch

BLACK

BLACK

BLACK

RED

WHITE

YELLOW

YELLOW

*BLUE AND/OR GRAY

*BLUE AND/OR GRAY

YELLOW

*CONNECTING THE BLUE AND/OR GRAY WIRE TO NEUTRAL SETS THE COLOR OF THE LED INDICATOR.

CONNECT BLUE FOR BLUE INDICATOR, GRAY FOR RED INDICATOR, OR BOTH FOR MAGENTA INDICATOR.

BLUE AND/OR GRAY WIRE MAY BE CONNECTED TO NEUTRAL OR EARTH GROUND.  NEUTRAL IS RECOMMENDED.

GREEN

Line 120VAC, 60Hz

NOTE:

 It is normal for this switch to make a slight 

buzzing sound during operation. It is also normal for 

the switch and wall plate to feel warm to the touch.

SPECIFICATIONS

Reset to Factory Default Settings

To reset the Leviton UPB™ Wall Switch to factory default settings:

Model Number

40A00-1

Incandescent Loads, Inductive Loads, and Florescent Loads

Yes

Motor-Operated Appliances

Yes

Current Maximum

15A

Connections

18 GA

LED Indicator

Yes

Dimensions

4.1 x 1.75 x 1.45

Weight

0.25 lb.

Mounting

Standard J Box

Input Power

120 ± 12 VAC

Input Frequency

60 ± 3 Hz

Operating Temperature

-40 °F to 104 °F

Step

Operation

1

On the Leviton UPB™ Wall Switch that you want to reset to factory default, tap the rocker switch 

quickly 5 times.

2

The Leviton UPB™ Wall Switch will cycle the load one time and blink its LED blue to indicate that it 

is ready to be reset.

3

Tap the rocker switch quickly 10 times to reset to factory default setting.

4

The Leviton UPB™ Wall Switch will cycle the load one time and blink its LED red to indicate that it 

has been reset.

5

Tap the rocker switch once more to stop the LED from blinking.

DI-022-HL401-05A

AR2253

FCC Compliance

 

This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed 

to provide reasonable protection against harmful 

interference in a residential installation. This equipment 

generates, uses and can radiate radio frequency 

energy and, if not installed and used in accordance 

with the instructions, may cause harmful interference 

to radio communications. However, there is no 

guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful 

interference to radio or television reception, which can 

be determined by turning the equipment off and on, the 

user is encouraged to try to correct the interference by 

one or more of the following measures:

- Reorient or relocate the receiving antenna.

-  Increase the separation between the equipment and 

receiver.

-  Connect the equipment into an outlet on a circuit 

different from that to which the receiver is connected.

-  Consult the dealer or an experienced radio/TV 

technician for help.

LEVITON LIMITED WARRANTY

Leviton  warrants  to  the  original  consumer  purchaser  and  not  for  the  benefit  of  anyone  else  that  products  manufactured  by  Leviton  under  the  Leviton  brand  name  (“Product”)  will  be  free  from  defects 

in  material  and  workmanship  for  the  time  periods  indicated  below,  whichever  is  shorter: 

•  OmniPro  II  and  Lumina  Pro:  three  (3)  years  from  installation  or  42  months  from  manufacture  date.

  

• OmniLT, Omni IIe, and Lumina: two (2) years from installation or 30 months from manufacture date. • Thermostats, Accessories: two (2) years from installation or 30 months from manufacture date.

  

•  Batteries:  Rechargeable  batteries  in  products  are  warranted  for  ninety  (90)  days  from  date  of  purchase. 

Note:

  Primary  (non-rechargeable)  batteries  shipped  in  products  are  not  warranted.  

Products with Windows

®

 Operating Systems:

 During the warranty period, Leviton will restore corrupted operating systems to factory default at no charge, provided that the product has been used as 

originally  intended.  Installation  of  non-Leviton  software  or  modification  of  the  operating  system  voids  this  warranty.  Leviton’s  obligation  under  this  Limited Warranty  is  limited  to  the  repair  or  replacement, 

at  Leviton’s  option,  of  Product  that  fails  due  to  defect  in  material  or  workmanship.  Leviton  reserves  the  right  to  replace  product  under  this  Limited  Warranty  with  new  or  remanufactured  product.  

Leviton will not be responsible for labor costs of removal or reinstallation of Product

. The repaired or replaced product is then warranted under the terms of this Limited Warranty for the remainder of 

the Limited Warranty time period or ninety (90) days, whichever is longer. This Limited Warranty does not cover PC-based software products. 

Leviton is not responsible for conditions or applications 

beyond Leviton’s control

Leviton is not responsible for issues related to improper installation, including failure to follow written Installation and operation instructions, normal wear and 

tear, catastrophe, fault or negligence of the user or other problems external to the Product

. To  view  complete  warranty  and  instructions  for  returning  product,  please  visit  us  at 

www.leviton.com

.

Use herein of third party trademarks, service marks, 

trade names, brand names and/or product names 

are for informational purposes only, are/may be the 

trademarks of their respective owners; such use is not 

meant to imply affiliation, sponsorship, or endorsement.

WEB 

VERSION

Reviews: