Appendix A: Troubleshooting
Diagnosing Switch Indicators
Power and Cooling Problems
If the power indicator does not turn on when the power cord is plugged in, you may
have a problem with the power outlet, power cord, or internal power supply.
However, if the unit powers off after running for a while, check for loose power
connections, power losses or surges at the power outlet, and verify that the fans on
the unit are unobstructed and running prior to shutdown. If you still cannot isolate the
problem, then the internal power supply may be defective.
Installation
Verify that all system components have been properly installed. If one or more
components appear to be malfunctioning (such as the power cord or network
cabling), test them in an alternate environment where you are sure that all the other
components are functioning properly.
Table A-1. Troubleshooting Chart
Symptom
Action
Power LED is Off
• Power supply is disconnected.
• Check connections between the switch, the power cord, and the wall
outlet.
• Contact your dealer for assistance.
Power LED is Amber
• Internal power supply has failed. Contact your local dealer for assistance.
Diag LED is Amber
• Power cycle the switch to try and clear the condition.
• If the condition does not clear, contact your dealer for assistance.
Link LED is Off
• Verify that the switch and attached device are powered on.
• Be sure the cable is plugged into both the switch and corresponding
device.
• Verify that the proper cable type is used and its length does not exceed
specified limits.
• Check the adapter on the attached device and cable connections for
possible defects. Replace the defective adapter or cable if necessary.
Summary of Contents for FGL-2870
Page 1: ...LevelOne FGL 2870 24 FE 4 GE Combo SFP L2 SNMP Switch Installation Guide Version 1 0...
Page 2: ......
Page 4: ...FGL 2870 E122009 WM R01 149100000059A...
Page 12: ...viii...
Page 22: ...Introduction 1 6 1...
Page 36: ...3 8 Installing the Switch 3...
Page 52: ...C 4 Specifications C...
Page 59: ......