background image

http://www.level1.com

  

                                                        

 

 

 

 

 FEP-0840 

8-Port Web Smart PoE Switch 

Quick Guide 

User Manual 

 

 

V1.0

 

Digital Data Communications Asia Co., Ltd. 

http://www.level1.com

 

Summary of Contents for FEP-0840

Page 1: ...http www level1 com 1 FEP 0840 8 Port Web Smart PoE Switch Quick Guide User Manual V1 0 Digital Data Communications Asia Co Ltd http www level1 com...

Page 2: ...orm self diagnostic test It takes about 10 seconds to complete the process Step4 Set your PC IP address to 192 168 2 100 same subnet 192 168 2 x as the web management Step5 Enter 192 168 2 1 default I...

Page 3: ...Update to power on the connected PoE AP device for Port 1 You may also click PoE Scheduling to select time schedule for Power on off scheduling control Step8 Refer to Chapter 4 for further networking...

Page 4: ...ion 11 3 5 Cabling Requirements 12 3 6 Power Connection 13 3 7 Installation Steps 13 3 8 Reset to Default 14 4 Web Management 16 4 1 Setup your computer for Web management 16 4 2 Web management 19 4 3...

Page 5: ...Priority Mode 40 4 8 2 Class of Service Configuration 41 4 9 Security 43 4 9 1 MAC Address Binding 43 4 9 2 MAC Address Scan 44 4 9 3 TCP UDP Filter 44 4 9 4 Web Management Filter 45 4 10 Spanning Tre...

Page 6: ...http www level1 com 6 Appendix B Troubleshooting 54 B 1 Can NOT Access Web Page 54 B 2 Forget IP Address User ID and Password 54...

Page 7: ...e Ethernet ports are all turned off initially and can be turned on per port basis through the web management to power on the corresponding remote PoE device The powered PoE device can be any equipment...

Page 8: ...ment 16 1 LED Indicators LAN PoE for 8 ports PWR for system power Built in push button for default reset AC power on off switch OVP OCP OTP protections 2 1 Power on Switch The POE SWITCH is equipped w...

Page 9: ...on of the web management switch After unpacking and taking out the entire package contents please check whether you have got the following items POE SWITCH Unit One AC Power Cord One CD ROM for Quick...

Page 10: ...on their network All the 8 ports support network speeds of either 10Mbps or 100Mbps and can operate in half and full duplex transfer modes These ports also support the automatic MDI MDIX crossover det...

Page 11: ...RFC standards for IEC 801 3 Level 2 3V M field strength The air temperature in the location should be within a range of 0 to 60 C The relative humidity in the location should not exceed 90 non condens...

Page 12: ...guring within the 10 100 BASE T cabling architecture the cable distance should be within 100m The cable requirement for 10 100BASE TX connection is listed in table as follows 10BASE T 100 ohm Category...

Page 13: ...tallation Steps This section describes the step by step procedures for PoE setup Step1 Connect the PoE AP device to LAN port 1 and your PC to LAN port 8 of the POE SWITCH as the above connection Step2...

Page 14: ...use the reset button for the factory default settings Please follow the steps to reset the Web Smart Switch back to the original default values Step1 Turn on the web smart switch Step2 Press and hold...

Page 15: ...http www level1 com 15 Step5 Enter 192 168 2 1 from PC web browser to connect to web management Step6 Enter admin for username and system for password and click OK button to login to web management...

Page 16: ...same subnet and subnet mask as the switch in order to configure the switch through PC web browser To find out the IP address information for your computer please run Command Line window in WinNT 2000...

Page 17: ...e network connection status icon on the task bar This should bring up a window showing the status of the current network connection If there is no network status icon on the task bar please go to the...

Page 18: ...nish entering the IP Note1 An alternative configuration is to change the switch IP address into the same subnet as the computer This can be done in the Section 4 3 Admistrator for setting new switch I...

Page 19: ...ick the OK button to login to the web management page as follows Menu Bar The Menu bar is on the left side of the screen where you may click to configure management functions Most configurations for a...

Page 20: ...ctions as the following Authentication Configuration System IP Configuration System Status Load Default Setting Firmware Update Reboot Device 4 3 1 Authentication Configuration This page shows the inf...

Page 21: ...0 Gateway Assign the network gateway for the web smart switch If you change the IP address of this switch and then press Update It will show update successfully then press Reboot button It will enter...

Page 22: ...ehavior 4 3 5 Firmware Update User need to enter the password twice and press Update button to update the firmware The smart switch will erase the flash memory There is a self protection mechanism in...

Page 23: ...ot Device Click Confirm button to reboot the device Note The reboot is for software base instead of hardware base 4 4 PoE This PoE section describes the PoE functions and display the power on off stat...

Page 24: ...http www level1 com 24 4 4 2 PoE Power Delay This PoE power on off will be delayed in accord with the delay mode...

Page 25: ...http www level1 com 25 4 4 3 PoE Scheduling The PoE on off control will be scheduling in accord with the schedule mode...

Page 26: ...en the Auto Negotiation column is set as Disable users have to set the connection speed to the ports ticked Duplex When the Auto Negotiation column is set as Disable users have to set the connection m...

Page 27: ...the network throughput and it s recommended to set only one destination port in a network Monitored packets 1 Disable means this function is disabled 2 RX means copy the incoming packets of the selec...

Page 28: ...ports and destination ports is set the lower network throughput is available for normal traffic 4 5 3 Bandwidth Control This page allows the bandwidth setting for each port The TX rate and Rx rate ca...

Page 29: ...ber of the port1 4 is set to 10 20 30 40 respectively and Speed base is set to low The real bandwidth comes from the formula of 32Kbps 10 32Kbps 20 32Kbps 30 and 32Kbps 40 respectively After the updat...

Page 30: ...r of the port1 4 is set to 10 20 30 40 respectively and Speed base is set to High The real bandwidth comes from the formula of 512Kbps 10 512Kbps 20 512Kbps 30 and 512Kbps 40 respectively After the up...

Page 31: ...umber of the port 5 port 8 is set to 50 60 70 80 respectively and Speed base is set to low The real bandwidth comes from the formula of 32Kbps 50 32Kbps 60 32Kbps 70 and 32Kbps 80 respectively after t...

Page 32: ...ber of the port 5 port 8 is set to 50 60 70 80 respectively and Speed base is set to high The real bandwidth comes from the formula of 512Kbps 50 512Kbps 60 512Kbps 70 and 512Kbps 80 respectively Afte...

Page 33: ...he bandwidth setting should be less than 196 if the bandwidth is set to high For 10Mbps link speed the bandwidth setting should be less than 20 if the bandwidth base is set to high Setting the bandwid...

Page 34: ...of broadcast packets is counted in every time unit One time unit is 500 us for 10Mbps speed and 5ms for 100Mbps The excessive broadcast packet will be discarded For those broadcast packets incoming fr...

Page 35: ...ection includes the management functions as the following VLAN Mode VLAN Member Multi to 1 Setting 4 6 1 VLAN Mode Two VLAN modes tag based and port based are supported Only one VLAN mode can be enabl...

Page 36: ...02 1Q tag of the outgoing packet of the selected port will not be sent Use this setting for your Network Connections to PCs The packet will send to the Port of VLAN Group member only 4 6 2 VLAN Member...

Page 37: ...rt with IDs from 100 and up Keep in mind that some switches use 1 as the default while others use 4095 or 4096 as default Starting with 100 gives you enough free room and less compatibility issues Ent...

Page 38: ...s updated multi to 1 setting will be void and vice versa The Disable port means the port will be excluded in this setting All the ports excluded in this setting are treated as the same VLAN group The...

Page 39: ...m the switch and the count of collision Receive packet Transmit packet This category shows both the received packet count excluding the incorrect packet and the transmitted packet count Receive packet...

Page 40: ...o identify such classes but without delivery guarantee like the quality of service QoS functions which are implemented in the network devices 4 8 1 Priority Mode There are three priority modes availab...

Page 41: ...t TOS DS 802 1p and physical port The user can select more than one item for each port Note that if more than one type of CoS is selected the switch will arrange the packet to the assigned queue accor...

Page 42: ...http www level1 com 42...

Page 43: ...e the port binding function you may enter the assigned MAC address select the port number and set the port binding to enable and then press update Port No Displays the port number being assigned the M...

Page 44: ...work administrator can optionally block some specific functions There are two kinds of protocol filter functions The Forward function forwards packets of the selected protocol and drops other protocol...

Page 45: ...http www level1 com 45 4 9 4 Web Management Filter 4 10 Spanning Tree...

Page 46: ...http www level1 com 46 4 10 1 STP Bridge Settings 4 10 2 STP Port Settings 4 10 3 Loopback Detection Settings...

Page 47: ...http www level1 com 47...

Page 48: ...erent options Port ID Among the trunk member ports the packet will be distributed based on the port ID SA Among the trunk member ports the packet will be distributed based on the source MAC address DA...

Page 49: ...http www level1 com 49 4 12 DHCP Relay Agent 4 13 NTP Setting...

Page 50: ...tch configuration The user can save the configuration file to a specified file name If the user wants to recover the original configuration which is saved at the specified path just enter the password...

Page 51: ...an option for the administrator to enable the queue aging function VLAN Striding By selecting this function the switch will forward uni cast packets to the destination port no matter whether destinati...

Page 52: ...aseTX Cat 5 UTP STP Filtering Forwarding Rates 100Mbps port 148 800pps 10Mbps port 14 880pps LED Indicators Per Port LAN PoE Per Unit PWR Power Input 100 240V AC 50 60Hz Web Management Features VLAN S...

Page 53: ...http www level1 com 53 Dimensions 266 160 44 mm L x W x H Humidity 10 to 90 RH non condensing Weight 1 6 kg Temperature Operating 0 to 60 Storage 20 to 90...

Page 54: ...eb Page Web Browser is a useful tool to configure the web smart PoE switch When you have problems in accessing the default IP address http 192 168 2 1 of web page one of the most possibility is that t...

Reviews: