Leuze
electronic
Installation
Leuze electronic
ODS 96
19
Preferred mounting in
connection to objects
with structured surface
Figure 5.2: Preferred mounting, objects with structured surface
View through a chase
Figure 5.3: View through a chase
If the ODS 96 has to be installed behind a cover, the chase has to have at
least the size of the optical glass cover. Otherwise, a correct measurement is
not possible or can not be guaranteed.
5.3
Teach-In
Notice
The teach-in procedure can be extended and facilitated through the optional
programming software.
Switching points can also be set through teach-in without using the software.
Connected to the teach-in procedure, differences occur between the ODS 96
M/S types with two switching outputs and the analog and digital device:
Teach-In procedure
ODS 96 M/V, ODS 96
M/D
©
Position the measured object at the desired distance. Connect the teach
input for
2
sec. to +U
B
. After that, connect the teach input to GND. The
switching output is tought.
The tought switching point represents the middle of the switching range of the
output.
These default values are preset:
• Function characteristics of the switching output: "light switching"
• Switching range: ± 2 mm with infrared devices and ± 10 mm with laser
devices
• Hysteresis: ± 1 mm with infrared devices and ± 5 mm with laser devices
These values can only be changed by using the programming software.