![Leuze electronic MLD 300 Original Operating Instructions Download Page 42](http://html1.mh-extra.com/html/leuze-electronic/mld-300/mld-300_original-operating-instructions_1884028042.webp)
Mounting
Leuze electronic
MLD 300, MLD 500
43
Height of the muting-sensor light beams
The same conditions apply as with sequence controlled 2-sensor muting see figure 6.11.
Select the height of the light beams of the muting sensors so that the transport material is detected and
not the pallet or transport device.
Otherwise, you must take additional measures to prevent people from entering the danger zone on top
of the pallet or transport device.
6.3
Mounting the safety sensor
Proceed as follows:
• Select the type of fastening, e.g. swivel mount see chapter 6.3.2 „BT-240 swivel mount (optional)“or
clamp bracket see chapter 6.3.3 „BT-P40 clamp bracket (optional)“.
• Have a suitable tool at hand and mount the safety sensor in accordance with the notices regarding
the mounting locations see chapter 6.3.1 „Suitable mounting locations“.
• If possible, affix safety notice stickers on the mounted safety sensor or device column.
After mounting, you can electrically connectsee chapter 7 „Electrical connection“, start up, align see
chapter 8 „Setting the device into service“, and test see chapter 9.1 „Before the initial start-up and following
modifications“the safety sensor.
6.3.1 Suitable mounting locations
Area of application: mounting
Tester: technician who mounts the safety sensor
Table 6.4:
Checklist for mounting preparations
Check:
Yes
No
Do the beam heights satisfy the requirement of EN 13855 see chapter 6.1.2 „Beam
heights and ranges“?
Is the safety distance to the hazard location maintained see chapter 6.1.3 „Calculating
the safety distance“?
Is the minimum distance to reflective surfaces maintained see chapter 6.1.5 „Minimum
distance to reflective surfaces“?
Is it impossible for safety sensors that are mounted next to one another to mutually inter
-
fere with one another see chapter 6.1.6 „Preventing mutual interference between adja
-
cent devices“?
Can the hazard location or the danger zone only be accessed through the protective
field?
Has bypassing the protective field by crawling under, reaching over, or jumping over
been prevented?
Do the transmitter and receiver connections point in the same direction?
Can the transmitter and receiver or transceiver and Deflecting Mirror be mounted verti
-
cally (bubble level) and at the same height on a flat surface?
Can the transmitter and receiver or transceiver and Deflecting Mirror be secured in such
a way that they cannot be moved or turned?
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]