Mounting
Leuze electronic
MLD 300, MLD 500
39
Mount the muting sensors so that the intersection point of their light beams is at the same height or high
-
er than the lowest light beam of the safety sensor (d7).
This prevents—or makes more difficult—manipulation with the feet since the protective field is interrupted
before the muting-sensor light beam.
6.2.5 Arrangement of the muting sensors for sequence controlled 2-sensor muting
With this muting operating mode, material transport is only permissible in one direction due to the arrange
-
ment of the muting sensors (see chapter 4.7.2).
Pre-mounted Muting Sensor Sets (accessories) for MLD safety sensors simplify the set-up of this muting
solution see figure 14.13
Figure 6.9: Arrangement of the muting sensors at height d7
To increase safety and make manipulation more difficult, MS1 and MS2 should, if possible, be
mounted at different heights (i.e. no point-shaped intersection of the light beams).
d7
Mounting instructions for MLD Muting Sensor Sets be downloaded on the Internet
.
WARNING
Risk of death by through incorrect arrangement of the muting sensors!
Only select sequence controlled 2-sensor muting for material exits (see chapter 6.2.5).