Commissioning and configuration
Leuze electronic
MA 235
i
67
TNT
35/7-2
4
V
12.4.6.6 Object 3000
h
Serial Line Mode
The object describes the function mode of the MA 235
i
.
Parameter value:
0 = Transparent Mode
1 = Collective Mode
12.4.6.7 Object 3001
h
Serial Settings
The object describes the serial RS 232 settings of the MA 235
i
.
Use Rotary Switch
Parameter value:
0 = use rotary switch (default)
1 = use EDS settings
RS 232 Baud Rate
Parameter value:
3 = 300
6 = 600
12 = 1200
24 = 2400
48 = 4800
96 = 9600 (default)
192 = 19200
384 = 38400
576 = 57600
1152= 115200