Specifications
Leuze electronic
MA 235
i
21
TNT
35/7-2
4
V
5
Specifications
5.1
General specifications
Electrical data
Interface type 1
CANopen, integrated switch,
BUS:
1x M12 connector (A-coded),
1x M12 socket (A-coded)
PWR/IO: 1x M12 connector (A-coded),
1x M12 socket (A-coded)
Interface type 2
RS 232
Service interface
RS 232, 9-pin Sub-D connector, Leuze standard
data format
Data bit: 8, parity: None, stop bit: 1
Switching input/output
1 switching input/1 switching output
device-dependent voltage
Operating voltage
18 … 30VDC (PELV, Class 2)
1)
Power consumption
Max. 5VA (without DEV, current consumption max.
300mA)
Max stress on the connector
(PWR IN/OUT)
3A
Hand-held scanner operating voltage4.75 … 5.25VDC / max. 1A
Indicators
CAN LED
green Bus state ok
red
Bus error
PWR LED
green Power
red
Collection error
Mechanical data
Protection class
IP 65 (with screwed-on M12 and connected Leuze
device)
Weight
700 g
Dimensions (HxWxD)
130 x 90 x 41mm / with plate: 180 x 108 x 41mm
Housing
Diecast aluminum
Connection
2 x M12: BUS IN / BUS OUT CANopen
1 connector: RS 232
1 x M12: Power IN/GND and switching input/output
1 x M12: Power OUT/GND and switching input/output
Environmental data
Operating temperature range
0°C … +55°C
Storage temperature range
-20°C … +60°C
Air humidity
Max. 90% rel. humidity, non-condensing
Vibration
IEC 60068-2-6, test FC