Configuration using configuration codes
Leuze electronic
Technical description LSIS 22x
69
TNT
35/7-2
4
V
7.5.21
Data Matrix code selection
By reading in one of the following configuration codes, reading of the
Data Matrix
code
type is activated or deactivated. In addition, it is possible to configure the number of digits
that are to be read (value range for number of digits: 1 … 3116, factory setting: 1 … 3116).
Figure 7.44: Configuration codes for activating/deactivating the Data Matrix code type
Notice!
To set the minimum or maximum number of digits, please first read in the above configura-
tion code and then the digits for the desired number of digits (see "Programming codes for
the configuration" on page 92). Conclude parameter entry by reading in the
Save
program-
ming code.
Notice!
For further code settings for the
Data Matrix
code type, please contact Leuze electronic.
Read code type Data Matrix ON
Read code type Data Matrix OFF
Data Matrix - standard settings
Data Matrix - minimum number of digits
Data Matrix - maximum number of digits