Leuze electronic GmbH + Co. KG
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
IT 1911i / IT 1981i - 03
[email protected] • www.leuze.com
Connecting the IT 1911i / IT 1981i to the MA 21
Required parts:
1x
IT 1911i ER-3 or IT 1981i FR-3
1x
50122431
Base for IT 19x1i
1x
50114517 KB 232-1 IT 190x
1x
50123862
Power supply unit for Base for IT 19x1i
1x
50035421
KB 021 Z
1x
50030481
MA 21 100
Pin assignments KB021 Z:
Core color:
Signal
Terminal in the MA 21:
Brown
(RXD)
26
White
(TXD)
27
Blue
(GND)
28
Red
(VCC)
Black
(GND)
Bare (shield)
(PE)
21
Procedure:
1.
Connect cable KB 021 Z to the MA 21… acc. to the above pin assignments.
2.
Connect the interface cable to cable KB 021 Z. Connect the interface cable and the power
supply unit to the base station (see "Connecting the IT 1911i / IT 1981i to the serial PC inter-
face").
3.
Scan the adjacent 2D code.
The hand-held scanner is set to the following transmission parameters:
RS 232 transmission with 9,600 baud, 7 data bits, 1 stop bit, even parity, postfixes
<CR><LF>.
4.
Return the hand-held scanner to the base station to apply the settings. This procedure is
concluded with audible confirmation signals.
Notice!
To charge the hand-held scanner, the power supply unit must be plugged in
and the hand-held scanner placed in the base station.
IT 1911i / IT 1981i
2D-code hand-held scanner with Bluetooth for industrial use