Error messages (P and M12 interfaces)
Leuze electronic
GS 754B
29
TNT
35/7-2
4
V
8
Error messages (P and M12 interfaces)
Errors vary depending on the configured measurement, analysis and output variants. The
errors are output at interfaces P and M12.
9
Service and support
24-hour on-call service at: +49 (0) 7021 573-0
Service hotline: +49 (0) 7021 573-217
Monday to Thursday, 8.00 a.m. to 5.00 p.m. (UTC+1)
Friday, 8.00 a.m. to 4.00 p.m. (UTC +1)
E-mail:
Return address for repairs:
Servicecenter Leuze electronic GmbH + Co. KG
In der Braike 1
D-73277 Owen
Germany
Fewer edges than
specified
More edges than
specified
Light path fully blocked
Serial
output
Modes 1 … 5
000
555
999
Mode 7
0
2047
0
Analog
current
Modes 1 … 5
3.5mA
>20mA
>20mA
Mode 7
0mA
Analog
voltage
Modes 1 … 5
1.75 V
>10V
>10V
Mode 7
0V