DMU318-400.W…-M12 - 01

2017/02

DMU318-1600.W…-M12 - 01

Technical data

Ultrasonic specifications

DMU318-400.W3/…-M12

DMU318-1600.W3/…-M12

Scanning range 

1)

1) At 20°C

50 … 400mm 

2)

 

2) Target: 200mm x 200mm plate

150 … 1600mm 

2)

 

Adjustment range

50 … 400mm

150 … 1600mm

Ultrasonic frequency

300kHz

230kHz

Typ. opening angle

Resolution

< 2mm

< 2mm

Direction of beam

90° to longitudinal axis

90° to longitudinal axis

Reproducibility

± 0.5% 

1)

 

3)

3) From end value

± 0.5% 

1)

 

3)

Switching hysteresis

1% 

3)

 1% 

3)

 

Analog output accuracy

1% 

3)

 1% 

3)

 

Temperature drift

5% 

4)

4) Over the temperature range -20°C … +70°C

5% 

4)

 

Timing

Switching frequency

10Hz

2Hz

Response time

500ms

500ms

Readiness delay 

< 900ms (analog output), 
< 500ms (switching output)

< 900ms (analog output), 
< 500ms (switching output)

Electrical data

Operating voltage U

5)

 

5) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC

10 … 30V DC (incl. ± 7% residual ripple) 

Residual ripple

±

7% of U

B

Open-circuit current

50mA

Analog output

Analog output

…/…C…

…/…V…

1 analog output 4 … 20mA
1 analog output 0 … 10V

Load resistance

Current output: R

L

500Ω, 

Voltage output: R

L

2kΩ 

Characteristic curve adjustment

1-point teach: teach in button 2 … 7s, 
2-point teach: teach in button 7 … 12s, 
Characteristic curve inversion: teach in button > 12s

Analog output error signal

Distance too small: approx. 3.8mA, 
Distance too large: approx. 11V / approx. 21mA

Switching output

Switching output / Function

…/4… 1 PNP transistor switching output 

OUT 1 (pin 4): NO contact preset

…/2… 1 NPN transistor switching output 

OUT 1 (pin 4): NO contact preset

Output current

Max. 100mA

Switching range adjustment

1-point teach: teach-in button 2 … 7s, 
2-point teach: teach-in button 7 … 12s

Changeover NO/NC

Teach-in button > 12s

Indicators

Yellow LED 

OUT2: object detected

Blue LED 

Analog OUT: object detected

Yellow/green or blue/green LED flashing

Teach-in / teaching error

Green LED

Object within the scanning range

Mechanical data 

Housing Plastic 

(PBT)

Active surface

Epoxy resin, glass fiber reinforced

Weight 75g

Ultrasonic transducer

Piezoceramic 

6)

6) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT)

Connection type 

M12 connector, 5-pin

Fitting position

Any

Environmental data

Ambient temp. (operation/storage) -20° … +70°C/-20° … +70°C 
Protective circuit 

7)

7) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection

1, 2, 3

VDE protection class

III

Degree of protection 

IP 67

Standards applied

EN 60947-5-2

Certifications

UL 508, CSA C22.2 No.14-13 

5)

 

8)

 

8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min, 

in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)

Diagrams

DMU318-400.W3/…-M12

DMU318-1600.W3/…-M12

Notes

Observe intended use!

This product is not a safety sensor 
and is not intended as personnel 
protection.

The product may only be put into 
operation by competent persons.

Only use the product in accor-
dance with its intended use.

-100

-50

0

50

100

0

100

200

300

400

500

y1

y2

Object distance x [mm]

Width

 y of th

e s

ound

 co

ne [mm

]

Typ. response behavior (plate 200x200mm)

-100

-50

0

50

100

0

100

200

300

400

500

y1

y2

Object distance x [mm]

W

idth y

 of the

 so

und

 co

ne [mm]

Typ. response behavior (rod Ø 25mm)

y1

y2

-300

-200

0

100

-100

200

300

0

400

800

1600

1200

Object distance x [mm]

Wi

dth y

 of the s

ou

nd c

one

 [mm]

Typ. response behavior (plate 200x200mm)

y1

y2

-300

-200

0

100

-100

200

300

0

400

800

1600

1200

Object distance x [mm]

Wid

th y o

f the s

ou

nd c

one

 [mm]

Typ. response behavior (rod Ø 25mm)

Object distance [mm]

Target (fixed):

plate or rod

Sound cone

= f (

α

,x)

DMU318…W

Summary of Contents for DMU318 W Series

Page 1: ...PN NO NC function reversible NEW Both outputs can easily be taught using a button NEW Stable plastic design NEW Temperature compensated scanning range 50 400mm 150 1600mm 10 30 V DC 4 20mA 0 10V Acces...

Page 2: ...utton 12s Indicators Yellow LED OUT2 object detected Blue LED Analog OUT object detected Yellow green or blue green LED flashing Teach in teaching error Green LED Object within the scanning range Mech...

Page 3: ...contact preset C Analog output 4 20mA V Analog output 0 10V Pin assignment of connector pin 5 gray cable wire Sync MUX K Synchronization multiplex input Connection technology M12 M12 connector 5 pin...

Page 4: ...rmally closed Close Far Far Close Dead zone Sensor OUT1 active Yellow LED ON Green LED OFF OUT1 not active Yellow LED OFF Green LED ON Distance Hysteresis Switching point Scanning range OUT1 not activ...

Page 5: ...th 2 point window teach as a function of the switching function 1 Place object at desired switching distance 1 First place object at desired switching distance for switching point 1 2 To adjust the ou...

Page 6: ...output is changed to the opposite state toggled First activate the previously described teach mode for output OUT 1 Changeover of the switching function 1 To change the switching function of output O...

Page 7: ...that is to be taught OUT1 or Analog OUT 1 Press the teach button for 2s to activate teach mode The yellow LED OUT 1 flashes at 1Hz While in this state output OUT 1 can be taught 2 To teach output Ana...

Page 8: ...ning range of 400mm 90mm scanning range of 1600mm 310mm 2 To adjust analog output Analog OUT press the teach button for 2 7s until the blue and green LEDs flash simultaneously at 3Hz 3 Release the but...

Page 9: ...of the same type are wired together in a network according to the following diagram The devices work in synchronous operation with a simultaneous transmission pulse The response time of the individual...

Page 10: ...factory setting 1 switching point at 400mm or 1600mm rising characteristic curve with spread over the entire scanning range Resetting to factory settings 1 When switching on the supply voltage during...

Reviews: