Technical data
Leuze electronic
DDLS 548i
70
Tab. 12.3:
Indicators and operational controls
Individual LEDs
Operating status LEDs, operating mode LEDs in the control
panel
Status display of the Ethernet connection
LED line (bar graph)
Received signal level (SIGNAL QUALITY) LEDs in the control
panel
Membrane keyboard
Operating mode selector switch [MODE] in the control panel
Tab. 12.4:
Mechanical data
Housing
Diecast aluminum
Optical inlet/outlet: glass
Optical window: glass
Connection technology
M12 connectors
Degree of protection
IP 65 acc. to EN 60529
Weight
1185 g
Dimensions
(H x W x D) 156 mm x 100 mm x 99.5 mm
Tab. 12.5:
Environmental data
Ambient temperature (operation)
-5 °C … +50 °C
Storage temperature
-35 °C … +70 °C
Air humidity
max. 90% rel. humidity, non-condensing
Vibration
IEC 60068-2-6
Shock
IEC 60068-2-27
Noise
IEC 60068-2-64
Electromagnetic compatibility
IEC 61000-6-2 and EN 1000-6-4
Industrial interference emission
This is a Class A product. In a domestic environment, this prod-
uct may cause radio interference. In this case the operator may
be required to take appropriate measures.
Tab. 12.6:
Conformity
Conformity
CE, CDRH
12.1.2 Device with heating
Specifications are the same as for device without heating with the following differences:
Tab. 12.7:
Electrical equipment
Current consumption
< 500 mA at 24 V DC (no load at switching output)
Warmup time
Minimum 30 min at +24 V DC and an ambient temperature of
-35 °C
Minimum conductor cross section
Conductor cross section of at least 0.75 mm² for the supply
voltage supply line
Tab. 12.8:
Environmental data
Ambient temperature (operation)
-35 °C … +50 °C