Mounting
Leuze electronic
DDLS 548i
30
NOTICE
You will achieve greater flexibility during basic installation and fine adjustment if you mount the
devices on C profile rails.
Ä
Detach the contour of the optical window from the drilling template along the perforation.
Ä
Affix the removed drilling template to the optical window of the mobile device using the supplied self-ad-
hesive labels.
Ä
Switch on the alignment laser of the stationary device. Activate the LAS (Alignment laser) operating
mode to switch on the alignment laser (see chapter 6.1 "Setting the operating mode").
Ä
Move the mobile device on the lifting axis in manual operation to maximum distance.
Ä
Align the stationary device using the alignment screws (see chapter 3.1.1 "Device construction",
point 11 and point 12) and, if necessary, using the C-profile rails.
ð
The target spot of the alignment laser must be in the center of the drilling template on the mobile
device.
Ä
Move the mobile device on the lifting axis in manual operation to minimum distance.
ð
The target spot of the alignment laser must not extend beyond the outer ring of the drilling template
on the mobile device.
ð
If necessary, realign the stationary device.
Ä
Switch off the alignment laser of the stationary device. Activate the AUT (Automatic) operating mode to
switch off the alignment laser (see chapter 6.1 "Setting the operating mode").
Ä
Affix the detached drilling template to the optical window of the stationary device using the supplied
self-adhesive labels.
Ä
Switch on the alignment laser of the mobile device. Activate the LAS (Alignment laser) operating mode
to switch on the alignment laser (see chapter 6.1 "Setting the operating mode").
Ä
Move the mobile device on the lifting axis in manual operation to maximum distance.
Ä
Align the mobile device using the alignment screws (see chapter 3.1.1 "Device construction", point 11
and point 12) and, if necessary, using the C-profile rails.
ð
The target spot of the alignment laser must be in the center of the drilling template on the stationary
device.
Ä
Move the mobile device on the lifting axis in manual operation to minimum distance.
ð
The target spot of the alignment laser must not extend beyond the outer ring of the drilling template
on the stationary device.
ð
If necessary, realign the mobile device.
Ä
Switch off the alignment laser of the mobile device. Activate the AUT (Automatic) operating mode to
switch off the alignment laser (see chapter 6.1 "Setting the operating mode").
Ä
Remove the drilling template from the stationary device.
ð
This concludes the mounting of the devices in the lifting axis.
Further procedure:
• Perform the fine adjustment for the lifting axis (see chapter 6.2 "Fine adjustment").
4.3
Mounting without alignment laser
Ä
Observe the mounting instructions (see chapter 4.1 "Mounting instructions").
NOTICE
You will achieve greater flexibility during basic installation and fine adjustment if you mount the
devices on C profile rails.