Device description
Leuze electronic
CSL 710
12
3.4.2 Display on the receiver control panel
Located on the receiver is an OLED display which serves as a function indicator.
Figure 3.3: OLED display on the receiver
The type of display on the OLED display is different for the following operating modes:
• Alignment mode
• Process mode
Display indicators in alignment mode
In alignment mode, the OLED display shows the received signal level of the first active logical beam (FB)
and of the last active logical beam (LB) via two bar graph indicators.
1
Evenly aligned light curtain
2
No reception signal from first beam (FB); good reception signal from last beam (LB)
3
Marker for the minimum signal level which is to be achieved
Figure 3.4: OLED display on the receiver in alignment mode
Display indicators in process mode
In process mode, the upper line shows the number of interrupted beams (TIB) and the lower line shows
the logic state of the digital outputs. The value to be displayed is configurable.
1
Total of interrupted beams
2
Logic state at pin 2 (0 = not active, 1 = active)
3
Logic state at pin 5 (0 = not active, 1 = active)
4
Logic state at pin 6 (0 = not active, 1 = active)
5
Logic state at pin 7 (0 = not active, 1 = active)
Figure 3.5: OLED display on the receiver in process mode
If the control panel is not used for several minutes, the display darkens and switches off. Press
a function button to again make the display visible. Settings for visibility, display duration, etc.
can be changed via the Display menu.
1
2
3
1
2
3
4
5