Electrical connection
Le
u
ze electronic
BCL
3
00
i
\ BCL
3
01
i
7
9
TNT
35/7-2
4
V
7.2.2
MK 300 terminal hood with
s
prin
g
-loaded terminal
s
The MK
3
00 termin
a
l hood m
a
ke
s
it po
ss
i
b
le to connect the BCL
3
00
i
directly
a
nd witho
u
t
a
ddition
a
l connector
s
. The MK
3
00 fe
a
t
u
re
s
three c
ab
le le
a
d-thro
u
gh
s
in which the
s
hielding
connection for the interf
a
ce c
ab
le i
s
a
l
s
o loc
a
ted. The BCL
3
00
i
i
s
a
l
s
o to
b
e config
u
red
when the MK
3
00 i
s
in
a
clo
s
ed
s
t
a
te vi
a
a
Mini-B type U
S
B
s
ocket f
u
nctioning
as
the
s
ervice
interf
a
ce. P
a
r
a
meter memory i
s
integr
a
ted into the MK
3
00 which tempor
a
rily
s
tore
s
the
s
etting
s
of the BCL
3
00
i
in the c
as
e of repl
a
cement
a
nd tr
a
n
s
mit
s
them to
a
new device.
Fig
u
re 7.
3
:
BCL
3
00
i
- MK
3
00 termin
a
l hood with
s
pring-lo
a
ded termin
a
l
s
Notice!
The integrated parameter memory for simple exchange of the BCL 300
i
is located in the
MK 300.
Cable fabrication and
s
hieldin
g
connection
Remove
a
pprox. 7
8
mm of the connection c
ab
le
s
he
a
thing. 15mm of
s
he
a
th of the
s
hielded
line m
us
t
b
e freely
a
cce
ss
i
b
le.
Fig
u
re 7.4:
C
ab
le f
ab
ric
a
tion for MK
3
00 termin
a
l hood
Termin
a
l hood
MK
3
00
SERVICE
2
1 3 5
4
GND
D+
D-
VB
ID
Mini-B U
S
B
s
ocket
(
b
ehind protective c
a
p)
Termin
a
l
b
lock
PW
R
/
S
W I
N
/O
UT
Termin
a
l
b
lock
HO
S
T /
BU
S
IN
Termin
a
l de
s
ign
a
tion
MK
3
00
≈ 55 mm
≈ 8 mm
≈ 15 mm