34
ASM
EN
EN
FR
IT
ES
NL
PL
Terminal assignments of AS-i safety monitors ASM2E/1 and ASM2E/2
Terminal
Signal / description
Electrical connection
AS-i+
Connection to the AS-interface
bus
AS-i–
AS-iS+
Safe AS-interface output for
actuator monitoring or coupling
of another AS-interface net-
work
AS-iS–
L+
+24V DC / supply voltage
M
GND / reference ground
FE
Functional earth
1.Y1
EDM 1 / input of external de-
vice monitoring circuit, output
circuit 1
1.Y2
Start 1 / start input, output
circuit 1
1.13
1)
Output switching element 1,
output circuit 1
1.14
1.23
1)
Output switching element 2,
output circuit 1
1.24
1.32
Message output 1 "Safety on",
output circuit 1
2.Y1
EDM 2 / input of external de-
vice monitoring circuit, output
circuit 2
2.Y2
Start 2 / start input, output
circuit 2
2.13
1)
Output switching element 1,
output circuit 2
(
only ASM2E/2!
)
2.14
2.23
1)
Output switching element 2, output circuit 2 (
ASM2E/2 only!
)
2.24
2.32
Message output 2 "Safety on", output circuit 2