SSI interface
54
AMS 307
i
Leuze electronic
9.1.2
Cable length as a function of the data rate
Only shielded and twisted pair
lines (pin 1 with 2 and pin 3 with 4) are permitted as data
lines for the SSI interface (see chapter 9.2 "SSI - electrical connection").
The shielding must be connected at both ends.
Do not lay the cable parallel to power cables.
The maximum possible cable length is dependent on the cable used and the clock rate:
Table 9.1:
Max. cable length as a function of the clock rate
9.2
SSI - electrical connection
Figure 9.2:
SSI - electrical connection
Notice!
To connect the SSI interface we recommend our ready-made SSI cables, see chapter 11.4.5.
Data rate
80kBit/s
100kBit/s
200kBit/s
300kBit/s
400kBit/s
500kBit/s
1,000kBit/s
Max. cable length (typical)
500m
400m
200m
100m
50m
25m
10m
SSI
CLK+ 3
2
1
4
FE
DATA-
CLK-
DATA+
5
SSI connector (5-pin plug, B-coded)
Pin
Name
Remark
1
DATA+
+ Data line SSI (output)
2
DATA-
- Data line SSI (output)
3
CLK+
+ Clock line SSI (input electrically insulated)
4
CLK-
- Clock line SSI (input electrically insulated)
5
FE
Functional earth
Thread
FE
Functional earth (housing)