Electrical connection
Leuze electronic
AMS 307
i
37
TNT
35/7-2
4
V
Notice!
Degree of protection IP65 is achieved only if the connectors and caps are screwed into place!
Described in detail in the following are the individual connections and pin assignments.
7.2
PWR – voltage supply / switching input/output
Table 7.1:
PWR pin assignment
Further information on configuring the input/output can be found in display menu structure
level 2, menu item "I/O" in the appendix of the manual.
7.3
SSI
Table 7.2:
SSI pin assignment
PWR (5-pin plug, A-coded)
Pin
Name
Remark
1
VIN
Positive supply v18 … +30VDC
2
I/O 1
Switching input/output 1
3
GND
Negative supply voltage 0VDC
4
I/O 2
Switching input/output 2
5
FE
Functional earth
Thread
FE
Functional earth (housing)
PWR
I/O 2
I/O 1
3
2
1
4
5
GND
VIN
FE
M12 plug
(A-coded)
SSI (5-pin plug, B-coded)
Pin
Name
Remark
1
DATA+
+
Data line SSI (output)
2
DATA-
-
Data line SSI (output)
3
CLK+
+
Clock line SSI
(input electrically insulated)
4
CLK-
-
Clock line SSI
(input electrically insulated)
5
FE
Functional earth
Thread
FE
Functional earth (housing)
SSI
CLK+ 3
2
1
4
FE
DATA-
CLK-
DATA+
5
M12 connector
(B-coded)