Installation and mounting
22
AMS 307
i
Leuze electronic
The reflectors are mounted stationary and in parallel on one plane.
Both AMS 307
i
move independently of one another at different or the same dis-
tances to the reflectors.
Measurement distance
up to 120m
: minimum parallel spacing
X
≥
600mm
Notice!
Please note that when the AMS 307
i
are mounted in a mobile manner, travel tolerances could
cause the two laser light spots to move towards each other.
Take the travel tolerances of the vehicle into account when defining the parallel spacing of
adjacent AMS 307
i
.
5.2.3
Parallel mounting of AMS 307
i
and DDLS optical data transmission
The optical data transceivers of the DDLS series and the AMS 307
i
do not interfere with one
another. Depending on the size of the used reflector, the DDLS can be mounted with a
minimum parallel spacing of 100mm to the AMS 307
i
. The parallel spacing is independent
of the distance.