Display and control panel AMS 307i
Leuze electronic
AMS 307
i
45
TNT
35/7-2
4
V
SSI submenu
Position value submenu
Table 8.2:
SSI submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Activation
ON / OFF
Activates or deactivates the AMS 307
i
as an SSI participant.
ON
Coding
Binary/gray
Specifies the output format of the measurement value.
Gray
Number of data
bits
24-bit/25-bit/26-bit
The measurement value can be displayed on the SSI interface in this data
width.
24 bit
SSI resolution
0.001mm / 0.01mm / 0.1mm / 1mm / 10mm / free resolution
The measurement value can be displayed in these resolutions.
0.1mm
Error bit
ON/OFF
This parameter determines whether an error bit is also attached to the
"number of data bits". The error bit is the LSB and is not converted in the
case of gray representation of the measurement value.
ON
Error bit function
The error bit can be set with the following status messages:
Overflow / intensity (ATT) / temperature (TMP) /laser (LSR) /
plausibility (PLB) / hardware (ERR)
In the case of multiple namings, the individual states in the error bit are
processed in an OR function.
Plausibility
(PLB)
Hardware
(ERR)
Update rate
1.7 / 0.2ms
1,7
Clock frequency
50 - 79kHz / 80 - 800kHz
Selection of the clock frequency.
80 - 800kHz
Table 8.3:
Position value submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Measurement
unit
Metric/Inch
Specifies the units of the measured distances
Metric
Count direction
Positive/Negative
Positive: The measurement value begins at 0 and increases with increas-
ing distance.
Negative: The measurement value begins at 0 and decreases with
increasing distance. Negative distance values may need to be compen-
sated with an offset or preset.
Positive
Offset
Output value=measurement value+offset
The resolution of the offset value is independent of the selected "Reso-
lution position" and is entered in mm or inch/100. The offset value is
effective immediately following entry. If the preset value is activated, this
has priority over the offset. Preset and offset are not offset against each
other.
0mm
Preset
The preset value is accepted by means of teach pulse. The teach pulse
can be applied to a hardware input of the M12 PWR connector. The hard-
ware input must be appropriately configured. See also configuration of
the I/Os.
0mm