Selecting a subfunction and changing the setting
1.
Rock to left or right to select the desired subfunction.
2.
Press rocker push button in middle position. The currently set value is displayed statically.
3.
Rock to right or left to display the selectable adjustment values - these flash slowly.
4.
Accept the new value by pressing the rocker push button in the middle position.
Fast flashing indicates that the new value is accepted.
5.
Automatic return to the heading for the subfunction.
6.
Press again to statically display the previously selected value.
Description of the subfunctions
Subfunction
Possible settings /
value range
Factory setting
(default)
Explanation
rESP
SPd
Select
response time
t
rESP
=
10
μ
s
(signal range
XHS
)
1)
15
μ
s
(signal range
HS
)
1)
50
μ
s
(signal range
S
)
250
μ
s
(signal range
LR
)
1000
μ
s
(signal range
XLR
)
1) only available in devices without
IO-Link interface
250
μ
s
The response time is the max. time required by the switching output to
switch to the active state following a signal change at the input.
From this, the switching frequency can be calculated as follows:
Notice: A change to the response time is equivalent to a change to the
signal range. The response times of 10μs and 15μs can only be para-
meterized in devices without IO-Link interface.
GAIn
SEL
Select
gain
Gain stage
Gn 1
…
Gn 8(Gn32)
;
Auto
GAIn
Auto
GAIn
The gain stage can be set either by manually presetting a value between
Gn 1
…
Gn 8(Gn32)
or automatically by selecting
Auto GAIn
. The left, red
display shows the current signal value.
The gain stage should be selected so that the signal value is approximately
in the middle of the display area.
For devices without IO-Link
interface, the gain value can be set in
8 levels
.
For devices with IO-Link
interface, a higher resolution for the gain setting
is available with
32 gain steps
.
If
Auto GAIn
is selected, the device automatically determines the optimum
gain setting
during teaching
.
tch
SEL1
Select
teach mode
Teach modes
1 Pt
tch
(static),
2 Pt
tch
(static),
dYn
tch
(dynamic)
1 Pt
tch
Presetting a suitable teach process.
To trigger the teach event, see
Teaching operating mode
.
1-point teach, static
: during teaching, the current signal value is accepted
as the new switching threshold. Actuate the rocker push button to make fine
adjustments to the threshold.
2-point teach, static
: the switching threshold is calculated at approxi-
mately midway between two signal values, e.g., teach to two different
objects or teach to the same object at two different distances from the
probe. Example: signal value 1 = 100digits, signal value 2 = 400digits
Switching threshold = 280digits. Actuate the rocker push button to
+
or
-
to make fine adjustments to the threshold.
Dynamic teach
: suitable for processes that cannot be stopped for teaching.
When the teach event is started, the sensor begins to scan the signal values.
On the left, red display, the signal values are constantly displayed. At the end
of the teach event, the switching threshold is calculated at approximately
midway between the smallest and largest signal value.
Auto
thr
Threshold
tracking
Tracking the switching threshold
oFF
(aus),
On
(ein)
oFF
The function is only available during dynamic teaching. If the function is
switched on, the switching threshold is automatically and continuously opti-
mized by the sensor in such a way that maximum functional reliability is
ensured.
This can be used to compensate for, e.g., soiling or process changes.
Warning message
:
thr
ALrt
: The limit of threshold tracking is reached - the sensor contin-
ues to operate. Cleaning and, if necessary, alignment of the
fiber optics recommended
Error message
:
thr
Err
:
The limit of threshold tracking is exceeded -
the sensor
stops operating
. Cleaning and, if necessary, alignment of
the fiber optics urgently necessary
OFF
dLY
Switch-off
delay
0
(off),
1
…
9999
ms
(milliseconds)
0
Switch-off delay
(OFF Delay):
Individually adjustable from 1 … 9999ms.
Combination options
Combining timing functions
OFF
ISho
Passing contact
OFF
0
(off),
1
…
9999
ms
(milliseconds)
0
Passing contact on fall-back
(OFF 1-Shot):
Individually adjustable from 1 … 9999ms.
Combination options
Combining timing functions
On
dLY
Switch-on
delay
0
(off),
1
…
9999
ms
(milliseconds)
0
Switch-on delay
(ON Delay):
Individually adjustable from 1 … 9999ms.
Combination options
Combining timing functions
f =
1
2
•
t
rESP
[Hz]
LV463.XV