2018/06
Synchronous operation of multiple amplifiers / operation with activation input
If may also be necessary to query multiple light axes
simultaneously
(synchronously) . There are two ways to do this:
Model 1:
Wiring and adjustment according to section
Multiplex operation of multiple amplifiers
, but all slaves receive an
identical address
from 1 … 5
. Result: Master and slaves have a time offset of 1.5 ms; slaves with the same address operate synchronously.
Model 2:
Synchronous operation through an external activation signal at the
multi funct
input (pin 2/ws-WH). Subfunction setting:
Function
:
InP
SEL
multi funct
input
SYnc
PLc
activation
input
multi funct
activation input
(pin 2/ws-WH)
Transmitter
OFF
Transmitter
OFF
Transmitter
ON
The transmitter is
deactivated with a high
signal
. The transmitter is
activated without
actuation
or
with a low signal
.
LV463.XV