Leuze electronic 50133962 Manual Download Page 2

LV463.XV 1SWO - 02

2018/06

Technical data

Optical data 

Throughbeam 
principle

Scanning principle

Operating range/scanning range 

1)

1) Range/scanning range depending on the fiber optics used

Up to 1700mm

Up to 450mm

Light source

LED (modulated light)

Wavelength

660nm (visible red light)

Timing

Readiness delay 

500ms

Signal range

Extra High Speed 
(XHS) 

2)

2) The modes 

Extra High Speed

 (response time 10μs) and 

High Speed

 (response time 15μs) are only available in

models without IO-Link interface

High Speed 
(HS) 

2)

 

Speed 
(S)

Long Range 
(LR)

Extra Long Range 
(XLR)

Response time 

10μs

15μs

50μs

250μs

1000μs

Switching frequency 

3)

3) With a duty cycle of 1:1

50kHz

33kHz

10kHz

2kHz

0.5kHz

Display area (digits)

0 … 4000

0 … 4000

0 … 4000

0 … 9999

0 … 9999

Electrical data

Operating voltage U

B

 

4)

4) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC

12 … 24VDC ± 10%

Residual ripple

10% of U

B

Open-circuit current

40mA @ 24VDC

Switching output

…/4…
…/2…

Pin 4/bk:

PNP

Pin 4/bk:

NPN

…/L4…

Pin 4/bk:

IO-Link SIO mode, Push-pull 
(PNP light switching, NPN dark switching)

Pin 4/bk:

IO-Link COM2 mode

Pin 2/wh: PNP dark switching

Function 

Light/dark switching, adjustable by means of a switch

Switching output time functions

Switch-on/-off delay, 
passing contact (on actuation or fall-back),
(combinations are limited 

 

Combinations of timing functions

)

Adjustable times (time functions)

0 … 9999ms

Signal voltage high/low

(U

B

-2.5V)/

2.5V

Output current

100mA

Sensitivity

Adjustable using the teach function or 

+

/

-

 buttons

Indicators

Yellow LED

Switching output active

Display

2 x 7-segment LED, 4-digit, 
Red:

signal strength, 

Green:

switching threshold

Mechanical data 

Housing 

ABS/PC black/red, transparent PC cover

Weight

50g with M8 connector, 
63g with 2000mm cable
70g with 150mm cable and M12 connector

Connection type

M8 connector, 4-pin, or 
2000mm cable, 4 x 0.25mm

2

, or 

150mm cable with M12 connector, 4-pin

Fiber optic connection

Clamp-mounting, 2 x Ø 2.2mm

Environmental data

Ambient temp. (operation/storage)   

-10°C … +55°C/-20°C … +85°C

Protective circuit 

5)

5) 2=polarity reversal protection, 3=short circuit protection for all outputs

2, 3

Degree of protection 

IP 50, NEMA 1

Standards applied

EN 60947-5-2

Certifications

UL 508, C22.2 No.14-13 

4)

 

6)

6) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.24A min, 

in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)

Additional functions

Sensor adjustment

Menu-driven using display and rocker push button

Notes

Explanation of the 
signal ranges

Extra High Speed (XHS) 

1)

:

 

Shortest response time; short-
est operating range; 
display area 0 … 4000

High Speed (HS) 

1)

Very short response time; 
short operating range; 
display area: 0 … 4000

Speed (S)

Short response time and range 
suitable for many standard 
applications; display area 
0 … 4000

Long Range (LR)

Good response time; long 
operating range; display area: 
0 … 9999

Extra Long Range (XLR)

Longest response time, lon-
gest operating range, display 
area 0 … 9999

NOTE

Detailed specifications on the range/
scanning range are enclosed in the 
data sheets of our fiber optics type 

KF

KFX

 or 

GF

.

1) only available in devices

without IO-Link interface

Observe intended use!

This product is not a safety sensor 
and is not intended as personnel 
protection.

The product may only be put into 
operation by competent persons.

Only use the product in accor-
dance with its intended use.

NOTE

A separate data sheet with supple-
mentary information on operation 
and configuration via IO-Link is avail-
able for the 

amplifier with IO-Link

You can find this in the Download 
area on the product page of the 
amplifier at 

www.leuze.com

.

LV463.XV

Summary of Contents for 50133962

Page 1: ...ration and switching output Connection via M8 connector cable or cable with M12 connector Up to 1700mm Up to 450mm 10 30 V DC Accessories available separately Plastic fiber optics KF KFX Glass fiber optics GF Ready made cables KB Mounting device BTU LV463 IEC 60947 IEC 60947 Dimensioned drawing A Clamping lever for fiber optic cable unlock in direction of arrow B Connection for fiber optics receiv...

Page 2: ...tor 63g with 2000mm cable 70g with 150mm cable and M12 connector Connection type M8 connector 4 pin or 2000mm cable 4 x 0 25mm2 or 150mm cable with M12 connector 4 pin Fiber optic connection Clamp mounting 2 x Ø 2 2mm Environmental data Ambient temp operation storage 10 C 55 C 20 C 85 C Protective circuit 5 5 2 polarity reversal protection 3 short circuit protection for all outputs 2 3 Degree of p...

Page 3: ...pin 2 white cable wire multi funct OUT2 T Multifunction input teach activation or multiplex operation 4 PNP transistor switching output light switching Connection technology Not specified Connection cable standard length 2000mm 4 wire M8 M8 connector 4 pin 150 M8 Cable length 150mm with M8 connector 4 pin 150 M12 Cable length 150mm with M12 connector 4 pin With one switching output and multifuncti...

Page 4: ...Operating and display elements The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage Alternatively the amplifier can also be mounted without a DIN rail using the mounting accessory and M3 screws DIN rail TS 35 35mm x 7 5mm DIN rail TS 35 35mm x 7 5mm Spring mounted DIN rail mount Slide switch switching output light LO dark DO switching Lever for fiber optic clamp Sl...

Page 5: ... output dark switching The switching behavior is the inversion of the light switching setting Rocker push button Set switching threshold Navigation in menu The rocker push button can be rocked to the right and to the left and pressed in the middle position Rock In the ADJ operating mode the switching threshold can be increased or decreased by rocking In the PRG operating mode rock to navigate in t...

Page 6: ... teach process To trigger the teach event see Teaching operating mode 1 point teach static during teaching the current signal value is accepted as the new switching threshold Actuate the rocker push button to make fine adjustments to the threshold 2 point teach static the switching threshold is calculated at approxi mately midway between two signal values e g teach to two different objects or teac...

Page 7: ...s can be synchronized with one another in multiplex operation Here exactly one master and 1 5 slaves are always needed Settings for master mA n number Defines that this unit functions as a master and a total of n sensors were wired in parallel Value range n 2 6 Example mA 4means unit is the master a total of 4 sensors are wired to one another via the multi funct multifunction input Setting for sla...

Page 8: ...ing threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Rising edge Falling edge Active state of the switching output Set delay time 0 9999ms LV463...

Page 9: ...pears on the red display In this case the signal value may be too small and cannot be accepted as a teach value Table with minimum teach values as a function of the setting Check object and or placement and repeat event 2nd appears on the green display the red display shows the current signal value Place object 2 or object at distance 2 and press the rocker push button within one minute The second...

Page 10: ...ction begins with the rising edge tTeach 20 80ms Operating mode selector switch locked The teach event begins with the fall ing edge 1 Static 1 point teach The current signal value is taken over as the teach value with the falling edge 2 Static 2 point teach The current signal value is taken over as teach value 1 with the falling edge 3 Dynamic teach The sensor begins to scan the sig nal values wi...

Page 11: ...funct multifunction inputs pin 2 ws WH are connected in parallel For settings see subfunctions Maximum 6 minimum 2 units 1 x master 1 5 slaves Each unit can be either a master mA or slave SL The master also requires the information on the number of units connected in parallel n 1 number of slaves Each slave also receives an individual address 1 5 max The master generates a timing signal on pin 2 o...

Page 12: ...n identical address from 1 5 Result Master and slaves have a time offset of 1 5 ms slaves with the same address operate synchronously Model 2 Synchronous operation through an external activation signal at the multi funct input pin 2 ws WH Subfunction setting Function InP SEL multi funct input SYnc PLc activation input multi funct activation input pin 2 ws WH Transmitter OFF Transmitter OFF Transmi...

Reviews: