RUN operating mode - normal operation
The
RUN
operating mode is the standard operating mode in which the sensor detects objects; it signals this accord-
ing to the set functions. If the selector switch for the operating mode is in the
RUN
position, no changes to the device
can be made via the operational controls. This setting is thus suitable for protection against unintended operation and
changes to device settings.
For IO-Link operation, the
RUN
operating mode must be set.
PRG operating mode - sensor adjustment
The LV463 can be adjusted to meet customer requirements with a simple menu-driven system.
To do this, set the
selector switch
for the
operating mode
to position
PRG
.
The menu consists of 13 successive subfunctions. Rock to right or left to freely navigate through the subfunctions.
Selector switch
Operating mode
RUN
:
Normal operation and IO-Link - no settings possible via the operational controls
ADJ
:
Press rocker push button: the set teach is executed.
Rock to left - right: change the switching threshold, left =
+
and right =
-
.
PRG
:
Menu-driven device setting via display and rocker push button
Selector switch
Switching output
LO
:
Switching output
light switching
:
If throughbeam fiber optics are installed, the switching output is active when the
light path is free; if a scanning system is installed, the switching output is active
when an object is detected. The status LED illuminates when the switching output
is active.
DO
:
Switching output
dark switching
:
The switching behavior is the inversion of the
light switching
setting.
Rocker push button
- Set switching threshold
- Navigation in menu
The
rocker
push
button can be rocked
to the right
and
to the left
and
pressed
in the middle position.
Rock
+, -
:
In the
ADJ
operating mode, the switching threshold can be increased (
+
) or
decreased (
-
) by rocking. In the
PRG
operating mode, rock to navigate in the
menu.
Button:
Press the rocker push button in the middle position to accept a setting made in
the
PRG
operating mode.
Indicator
Signal strength
In the
RUN
and
ADJ
operating modes, the display shows the current signal value.
In the
PRG
operating mode, information on menu navigation appears on the
display.
Indicator
Switching threshold
In the
RUN
and
ADJ
operating modes, the display shows the currently set
switching threshold. In the
PRG
operating mode, information on menu navigation
appears on the display.
Status LED (yellow)
Switching output state
LED
ON
Switching output active.
LED
OFF
Switching output inactive.
NOTE
The
multi funct
multifunction input always takes precedence over the
Operating mode
selector switch.
This means that the amplifier can be taught via the multifunction input (remote teach) in the
RUN
operating mode as well.
OFF
dLY
FctY
dEF
ZEro
OFSt
Func
SEL
InP
SEL
dISP
rEAd
On
ISho
OFF
ISho
On
dLY
GAIn
SEL
Verstärkung
auswählen
GAIn
SEL
tch
SEL
Teachart
auswählen
tch
SEL
rESP
SPd
Auto
thr
Antwortzeit
auswählen
rESP
SPd
Select
response time
Select
gain
Select
teach mode
Master-slave
assignment
Offset
calibration
Factory setting
Threshold
tracking
Switch-off delay
Passing contact
OFF
Start-up delay
Passing contact
ON
Turn read
direction 180°
multi funct
input
LV463.XV
High-speed amplifier with 1 switching output for fiber optics