9
Through the 2 holes on the ground glass
4.
holder, unscrew the 2 Allen screws hold-
ing the enclosure cap to the body of the
adapter. Use a flat object to pry off the en-
closure cap from the body of the adapter.
Clean the other side of the condenser.
5.
Clean the top surface of the prism.
6.
Put the enclosure cap back on and use the
7.
2 Allen screws to secure it in place again.
Do not over tighten them.
Put the front tube back on.
8.
NOTE:
Dust will not matter beyond this point,
unless it is a stain. To remove a stain, please send it
back to the factory for repair.
The warranty WILL
BE VOIDED if you perform step 9 and beyond.
Pull the black rubber wedge at the roof of
9.
the prism out with a pair of narrow pliers.
Take the battery compartment off and
10.
gently pull it out. Remember, the wires are
still attached to the battery compartment.
Lift the prism up by using the index finger
11.
and the thumb.
Clean the prism with lens cleaning solu-
12.
tion and put it back.
Put the rubber wedge back.
13.
Put the enclosure cap back and use the 2
14.
allen screws to secure it in place. Do not
over tighten them.
Put the front tube back on.
15.
CAUTION
Summary of Contents for 35 extreme