www.lesterelectrical.com 4
01679N
5. Check the level of the electrolyte in conventional
liquid electrolyte lead acid batteries monthly.
Maintain the proper electrolyte level by adding
distilled or purified water when necessary.
Electrolyte levels lower during discharge and
rise during charge. Therefore, it is mandatory
that water be added to cells only when they are
fully charged; do not overfill. Old batteries
require more frequent additions of water than
new batteries.
6. Keep tops of batteries clean and dry to prevent
excessive self-discharge. Keep battery terminals
reasonably tight.
WIRING DIAGRAM
PARTS LIST FOR LESTRONIC II CHARGER, MODEL 19740, TYPE 24LC25-8ET, 120 VAC / 60 HZ
PART
NO.
QTY.
DESCRIPTION
31211S
1
CASE ASSEMBLY FOR DC W/ 2-#10 WIRES, (BASE WITH LOW VOLTAGE SWITCH)
26838S
1
CASE ASSEMBLY FOR DC W/ 2-#10 WIRES
27668S
1
CASE ASSEMBLY FOR DC W/ 1-10/2 CORD
19745S 1 TRANSFORMER
ASSEMBLY
04401S
1
CAPACITOR, 4.0 MFD, 660 VAC
16354S
1
HEATSINK ASSEMBLY W/ DIODES
08776S 1 FUSE
ASSEMBLY
24800S
1
ELECTRONIC TIMER KIT
*24228S
1
RELAY, FOR ELECTRONIC TIMER
**23385S
1
RELAY, FOR ELECTRONIC TIMER
16369S 1 AMMETER
31086S
1
SWITCH, LOW VOLTAGE START
(-95 OPTION ONLY)
02028S
1
BUSHING, STRAIN RELIEF AC CORD
27512S
1
BUSHING, KIT STRAIN RELIEF DC CORD
07874S
1
CORDSET, AC, 14/3, SJT, 12", MOLDED PLUG
25743S
1
CORDSET, DC, 2-#10, 45A POWERPOLE
(-91 OPTION)
27652S
1
CORDSET, DC, 10/2, SJO, NO PLUG
(-90 OPTION)
30443S
1
CORDSET, DC, 2-#10, SB50 RED PLUG
(-93 OPTION)
31051S
1
CORDSET, DC, 2-#10, 3/8" RINGS
(-95 OPTION)
* FOR USE WITH CHARGERS BUILT BEFORE 47/03