2 - EXPLODED VIEW AND PARTS LIST FOR FCR BRAKE MOTORS

2.1 - Exploded view for FCR brake motors

2.2 - Parts list for FCR brake motors

Ref. Description

Qty

Ref. Description

Qty

Ref. Description

Qty

1

Stator housing

1

11

Armature

1

40

Cover screws

3

2

Rotor shaft

1

15

Brake lining fan

1

46

Brake power supply unit

1

3

Front shield

1

17

External circlip

1

48

Motor terminal block

1

4

D.E. bearing

1

19

Keys

2

50

Sealing ring

1

5

Assembly rods

3 to 4

23

Steel cover (IA : ABS)

1

52

Terminal box

1

6

Internal circlip

1

24

Brake nut

1

60

D.E. key

1

7

Brake bearing

1

28

Brake springs

3 to 6

61

D.E. screw

1

8

Brake shield

1

33

Flexible washer

1

62

D.E. washer

1

10

Seal

1

34

Splined pins

3

367

Spring holder (frame132)

1

3

61

62

10

33

4

60

52

46

19

6

7

17

40

8

28

34 5

11 15

24

23

50

367

1

2

48

3 - SPARE PARTS

3.1 - Procedure

All orders for replacement parts must quote:

- the complete motor type, its number and the information given 

on the nameplate (see §1);

- number and designation of parts (the part numbers can be found 

on the exploded view § 2.1 and their description in the parts list 

§ 2.2).

In the case of flange mounted motors indicate the type of flange and its 

dimensions Ø PCD (B5 for flange-mounted, B14 for facemounted or 

MI integral mounting) and details of gearbox, when fitted.

In order to ensure the safety and good working order of our brake 

motors,  we  recommend  the  use  of  original  manufacturer 

replacement parts.
If this advice is not followed, the manufacturer cannot be held 

responsible for any subsequent damage.

3.2 - Wearing parts

Parts number

LS 71 FCR

(F)LS 80 FCR

(F)LS 90 FCR

(F)LS 100 FCR

(F)LS 112 FCR

LS 132 S FCR

(F)LS 132 M FCR

LS 160 FCR

4

6004 2RS

6204 2RS

6205 2RS

6206 2RS

6206 2RS

6208 2RS

6308 2RS

6309 2RS

7

6202 2RS

6204 2RS

6205 2RS

6205 2RS

6206 2RS

6206 2RS

6307 2RS

6307 2RS

10

20 x38 x 8

20 x 38 x 8

25 x 40 x 7

30 x 47 x 5

30 x 48 x 8

40 x 62 x 7

40 x 62 x 7

72 x 45 x 8

11

armature

15

brake lining fan

34

splined pin

50

101.19 x 3.53

120 x 4

136.12 x 3.53

136.12 x 3.53

164.7 x 3.53

164.7 x 3.53

209.14 x 3.53

209.14 x 3.53

Summary of Contents for FLS 100 FCR

Page 1: ...3 61 62 10 33 4 60 52 1 2 48 6 F LS ES IA MV PX FCR 3 phase asynchronous TEFV brake motors Maintenance 5025 en 2013 03 a en...

Page 2: ...return valve for example The following precautions must be taken before working on any stopped device mains voltage disconnected and no residual voltage present careful study of the causes of the sto...

Page 3: ...on number Notified Organisation Specific marking II 2D Ex tb IIIC Group II category 2 Dust or II 3D Ex tc IIIB Group II category 3 non conducting Dust T125 C Maximum surface temperature 125 C Db Dc Pr...

Page 4: ...motor type its number and the information given on the nameplate see 1 number and designation of parts the part numbers can be found on the exploded view 2 1 and their description in the parts list 2...

Page 5: ...oupling to the machine Desmantling reassembling the brake lever option DLRA Desmantling the brake lever DLRA Unscrew the handle of the lever 53 1 if fitted on the hand release lever Unscrew the cover...

Page 6: ...tly the state of the bearings must be checked Damaged bearings must be replaced as soon as possible to prevent worse damage to the motor and the driven equipment When one bearing needs to be replaced...

Page 7: ...mounted on the shaft faulty supply voltage Check terminal connection fault Check overload Check the current consumption against the current shown on the motor nameplate partial short circuit Check the...

Page 8: ...the shunts for separate power supply DEBRANCHER LE BLOC REDRESSEUR POUR ESSAI D ISOLEMENT OU DIELECTRIQUE DISCONNECT THE RECTIFIER CELL WHEN TESTING FOR CURRENT INSULATION OR DIELECTRIC 634139 fr en...

Page 9: ...ne according power supply and coil suivant alimentation et bobine according power supply and coil DEBRANCHER LE BLOC REDRESSEUR POUR ESSAI D ISOLEMENT OU DIELECTRIQUE DISCONNECT THE RECTIFIER CELL WHE...